20
Troubleshooting
Fault/error
Possible cause
Possible remedy
ETX-RDA does not work.
The green six-pin standard
connector is possibly not joined
together correctly.
Join the connector correctly
until it latches into position.
The ETX-RDA does not
function after connecting it to
the control system (on site).
No 24V voltage applied on site.
Incorrectly wired on site.
Test the voltage in the supply
cable.
Test the ETX-RDA with an
external electricity source.
Check the wiring on site.
The ETX-RDA does not open
or close correctly or does not
function after checking the
above points.
Error in the control of the chain
drive.
Perform a hard reset while
voltage is applied to the chain
drive. To do so, jumper 1st
cable (white) and 3rd cable
(green) for 2 seconds.
The chain length and the end
position may then have to be
reset by a qualified firm.
ETX-RDA does not function
after replacing the chain drive.
The green six-pin standard
connector is assigned
incorrectly.
Check whether the two
connector parts are assigned
correctly (see page 15).