![Printronix SLPA7000e Training Manual And Reference Manual Download Page 51](http://html1.mh-extra.com/html/printronix/slpa7000e/slpa7000e_training-manual-and-reference-manual_1603256051.webp)
Positioning The Media Sensors
51
The upper media sensor, located in the slot under the printhead cover
(see Figure 18 on page 49), should be located directly over the lower media
sensor.
The lower media sensor should not be placed in the path of media features
that could cause false gap detection or paper out faults. Such features are
dark pre-printing, rounded die cut label corners, and extraneous cut-outs.
Figure 20. Positioning the Lower Media Sensor in Relation to the Label
Avoid Rounded
Die Cut Label
Corner
Position the lower
media sensor in the
grey shaded area.
Avoid Pre-Printing
FEED