542-515revB
5
Printed in USA 10/10 © 2010
Product Holding Bin
DHB2SS-20/27
Setting the Temperature
The unit has two shelves, each with an upper and lower heater (four heaters total).
The factory pre-set for the upper heaters is 225°F.
The factory pre-set for the lower heaters is 195°F.
Each upper heater has a programmable range of 150° – 275°F.
Each lower heater has a programmable range of 150° – 225°F.
Use the control below and the following steps to set the setpoint temperature for each heater.
1
UPPER SHELF LED
This LED will be lit to indicate upper shelf is
selected.
PROG LED
This LED will be lit to indicate unit is in Program
Mode.
LOWER SHELF LED
This LED will be lit to indicate lower shelf is
selected.
ACTUAL TEMP BUTTON and LED
Press to display actual temperature for the
selected heater. LED will be lit when actual
temperature is displayed.
SETPOINT BUTTON and LED
Press to display setpoint temperature of a
selected heater. LED will be lit when setpoint
temperature is displayed.
TEMPERATURE DISPLAY
NOTE: The unit is preset to display temperature
in Fahrenheit. To display in Celsius, press and
hold the DOWN Arrow button immediately after
turning on the power switch. To switch back to
Fahrenheit, press and hold the UP Arrow button
after turning on the power switch.
UP/DOWN ARROW BUTTONS
Used with other buttons to scroll through heater
and temperature selections.
PRINCE CASTLE LOGO BUTTON
Press to enter temperature selections.
NOTE: To reset all times and temperatures to the factory settings, turn the unit off, then press and hold the UP and DOWN Arrow buttons simultaneously
while turning the unit back on. A “P” will appear in the display and all times and temperatures will be reset to original factory settings.
U225
Press the UP or DOWN Arrow button until the desired shelf LED
and upper (U) or lower (L) heater is selected.
2
Press the UP or DOWN Arrow button until the desired setpoint
temperature is displayed.
4
Press and hold the SETPOINT button and the PRINCE
CASTLE LOGO button for 5 seconds. The Program LED
will light.
3
Press the PRINCE CASTLE LOGO button to save the new
setpoint value. Repeat steps 2 – 5 to change the setpoint for any
other heater.
5