TEMP 275
CAL 265
presets loaded
129 C
Steamer 625-50
2
revA
3
Printed in USA
0
910
© 200
3
Steamer
625-
A
Temperature Adjustment
1
3
A. Press and hold the TEMPERATURE button. The display will
show the current temperature setting for Celsius (C) or
Fahrenheit (F).
B. While holding the TEMPERATURE button, press the C/F button
to change the setting between Fahrenheit and Celsius.
C. Release the TEMPERATURE button to store the new value.
Platen temperature can be set between 129°-152°C (265°- 305°F).
Pre-set at factory to 140°C (285°F) .
A. Press the UP or DOWN Arrow buttons to scroll to the
desired temperature.
B. Press the
Steamer
LOGO button to store the desired
temperature and exit the SET TEMP mode.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program mode without storing the change.
5
A. Press the UP or DOWN Arrow buttons until the temperature
readout matches the calibration reading.
B. Press the
Steamer
LOGO button to store the desired tem-
perature and exit CAL TEMP mode.
NOTE: Pressing the Product 3 button at any time exits the
Program mode without storing the change.
Loading factory presets restores the unit to factory settings and voids
all user programmed information.
A. During power up, press and hold both PRODUCT 1 and PRODUCT 4
buttons within 3 seconds. The display will flash PRESETS LOADED.
B. Release both buttons.
2
A. Press and hold the
Steamer
LOGO button first, then
press and hold TEMPERATURE button for approximately
6 seconds.
The display will show
SET TEMP
.
B. Press the
Steamer
LOGO button again to display the
current set temperature.
4
The CAL TEMP mode is used to calibrate the platen temperature
with an external meter connected to the meter plug inlet on the
bottom right side of the unit. Add ± 5°C (± 10°F) .
Repeat Step 2A
A. Press the UP and DOWN Arrow buttons to scroll to
CAL TEMP
.
B. Press the
Steamer
LOGO button again to display the current
calibration temperature.
C. Press the PRODUCT 2 button to zero any previous calibration
offset value. The display will now show the platen temperature
without any calibration offset.
255 F
TEMP 275
CAL 245
CAL TEMP
set temp
CAL 265
Factory Presets
. VERS XX.XX
View Firmware Version
Press and hold the
Seamer
LOGO button first, then press and
hold the START button.
The display will show the current firmware version.
Manual Reset
A hi-limit thermostat will turn off electrical power to the platen and
control circuits if the unit overheats.
Turn the unit off and allow to cool (approximately 10-15 minutes).
A manual reset is located on the back of the unit. Once the unit has
cooled sufficiently, press the manual reset and restart the unit.
NOTE: If the unit continues to shut-off due to overheating, contact your
authorized Prince Castle Service Agency.
Manual Reset
255
Default Factory Presets:
ON OFF Cycles
All
1
3
2