MECHANICAL INSTALLATION: 

Locate a suitable mounting  area for the Wind Control Panel, preferably close to the battery bank 
and maintaining the ability to view the meter and operate the controls. 

 

Panel Mount: 

The panel should be mounted in a clean and dry environment.  Be sure the mounting 

location is mechanically sound.  Allow adequate space behind the panel so that the components will 
not touch any surfaces, wires or other items.   In the back of this manual you will find a 1:1 cutout 
template to  assist  in installation.   Identify your  optimum mounting  location keeping  in mind  that 
adequate room will be needed for the large wire sizes (#10 - #8) to be terminated on the terminal 
block (TB-3).  Using the template, cut the large opening and drill the six mounting holes. 

 

ELECTRICAL INSTALLATION: 

 

1)  Wind  Turbine: 

Connect  the  wires  of  the  wind  turbine  (TB-3), 

Negative (Black) to Terminal 2 and Positive (Red) to Terminal 1 of the 
Control Panel using the appropriate wire size and crimps. The Green 
(Ground)  wire  of the  wind  turbine  should  not  be  connected  to the 
boat  grounding  system  but  instead  should  be  connected  to  the 
Negative wire (Black) of the wind  turbine  prior to connecting to the 
Control Panel Terminal 2.  If the ground wire is directly connected to 
the negative vessel buss or ground system, the wind turbine may not 
operate properly. 

 

Warning

 

ABYC   STANDARDS   AND   PRACTICES

   should   be   followed

 

during  the installation  along with  recommendations made in  the Air 
manual. This manual is made available to assist during installation and 
start up and is not intended to supersede the ABYC Standards or the 
other requirements and recommendations.

 

Summary of Contents for 2-ARAC-103

Page 1: ...In the RUN position it allows the wind turbine to operate and produce power while in the STOP position it places an electric brake on the wind turbine spindle stopping the rotation in this mode slight blade rotation may occur in strong winds The center position is an OFF position disconnecting the wind turbine but is not recommended The Ammeter monitors the wind turbines production The wind contro...

Page 2: ...the terminal block TB 3 Using the template cut the large opening and drill the six mounting holes ELECTRICAL INSTALLATION 1 Wind Turbine Connect the wires of the wind turbine TB 3 Negative Black to Terminal 2 and Positive Red to Terminal 1 of the Control Panel using the appropriate wire size and crimps The Green Ground wire of the wind turbine should not be connected to the boat grounding system b...

Page 3: ...TOP position Connect the battery feed wires from the Control Panel to the battery bank terminals Make sure all connections are tight and the wires are properly sized TROUBLESHOOTING 1 Wind Turbine is Cycling On Off When the battery bank is approaching full charge the wind turbine may start and stop frequently This is caused by the wind turbine attempting to do the final top off on to your battery ...

Page 4: ...ving the circuit breaker on and wind circuits active will deplete only a minor amount of energy from your battery during non energy producing periods and should not be of concern The wind system works in harmony together with other energy producing systems on board such as solar PV alternator or AC powered battery charger and therefore it is not necessary to turn off the wind circuit breaker when ...

Page 5: ... a tight battery compartment that houses vented wet cell batteries Must be in a dry compartment 3 Do not run wind generator wires in bundles that contain SSB radio antenna 4 Always place STOP RUNswitch on the WCP in STOP position prior to making connectionsto the WCP 5 Battery connectionis made last Wind Circuit Breaker on the WCP must be placed in the OFF position prior to making final connection...

Page 6: ...Lakewood CO 80215 primuswindpower com Pg 5 5 PWP Wind Control Panel Manual 2 ARAC 103 Appendix Wind Control Panel 1 1 Cutout Cut along dotted line Drill 6 Holes 3 16 inch 938 Quail Street ...

Reviews: