connected. While these ratings provide a wide range of installation options, Primex recommends advance testing of
any bell system prior to extensive product installation and conversion from any current solution.
• When using multiple bell controllers to control different sets of bells within a facility, testing should be always be
performed to confirm proper operation and to verify there is no bleed-over between multiple bell controllers. To
prevent bleed over from occurring, the best practice is to have a single bell controller per branch circuit.
• Bell controller terminals accept wire gauge from 16-26 AWG.
• When wiring the bell controller to a public address (PA) and/or bell system equipment, all power to the device and
equipment must be turned off.
• Bell controller must be installed indoors.
• Bell controller must not be used for medical, life-saving purposes, or for any purpose where its failure could cause
serious injury or the loss of life.
• Bell controller must not be used in any way where its function or failure could cause significant loss or property
damage.
• Bell controller must be configured with your OneVue account ID and network settings. Verify the device can
successfully connect to the network and check-in to OneVue at its install location.
Install location guidelines
When identifying the mounting location of a bell controller, consider the following guidelines.
• Requires a hardwired connection from the bell controller's terminal block to an existing PA or bell system, the two
must be in close proximity to each other.
• Wired Ethernet use: network port jack is located in close proximity to the install location.
• Power over Ethernet (PoE) use: PoE compliant network port jack is located in close proximity to the install location.
• AC power: an outlet is within 5 feet (1.52 m) from the install location.
• Install location is easily accessible for maintenance and clear from obstructions.
• Bell controller is shock and vibration resistant; however, be careful not to drop or install the device in a location
where it could be exposed to excessive vibration.
WARNING
Battery power is for backup use only. When solely operating on battery power (two AA Lithium 1.5V
batteries) its estimated battery life is up to a maximum of 24 hours.
Connect bell controller relays to public address (PA) or bell system
A Bell Controller has two independent relays that can be connected to your existing PA or school bell system. Each of
the relays has a separate Normally Open (NO) and Normally Closed (NC) input.
The removable terminal connector is provided for simple wiring. The wiring procedure is as follows:
1. Be sure to follow the installation requirements and installation location guidelines.
2. All power to the device and PA or bell system equipment must be turned off.