59
Error code Table-3
Error Condition
Error Code
Indication
Bus under voltage
F1
Step1: Please turn off AC and DC.
Step2: Restart after 10 minutes.
Step3: If it continues to occur, please
replace another inverter.
Bus over voltage
F2
Step1: Please turn off AC and DC.
Step2: Restart after 10 minutes.
Step3: If it continues to occur, please
replace another inverter.
Internal
communication loss
F3
It's inverter's master CPU and auxiliary
CPU communicates abnormally.
Master expect slave
firmware version not
correct
F4
It’s reserved code for other application.
EEPROM fail
F5
It’s reserved code for other application.
Consistent warning
F6
It's inverter's master CPU and auxiliary
CPU detect fail.
Inverter over current
F7
It's the Grid protection.
Check if it is wrong installing?
For example, L1 of the grid connected to
L1 and L2 of the inverter.