18 AP360/362 Label Applicator
Maintenance
Label edges fold over or catch on the sensor as they are applied to the container.
1.
Over time adhesive from the labels can build up on the sensor flag just above the
container rollers. Periodically clean the top of the sensor with a Q-tip and alcohol.
2.
Make sure the sensor is positioned in the middle of the the label.
Unclamp Liner Idler Roller.
When not in use, leave the Liner Idler Roller in the unclamped position. This will minimize
the possibility that permanent indentations will be made in the Liner Drive Roller.
Lubricate bearings.
Primera recommends oiling the four bearings associated with the Liner Drive Roller and Liner
Idler Roller. Oil these four bearings for every 50,000 containers labeled. They should only be
oiled after the first 50,000 containers as they are lubricated with a special grease at the factory.
One drop of any machine oil or motor oil for each bearing should be adequate. This mainte-
nance is optional but will increase the life of the applicators for heavy users who use the
applicator for several hours each day.
Clean Label Gap Sensor Flag.
Over time adhesive from the labels can build up on the sensor flag just above the container
rollers. Periodically clean the top of the sensor with a Q-tip and alcohol.
Swapping/Flipping the label/container guide positions to accommodate
narrower labels.
You can swap the positions of the container guides or the label guides to accommodate shorter
containers or narrower labels.
Label Guide Instructions
1.
Loosen one of the thumbscrews until it is removed. Hold your hand underneath guide plate
to catch the nut as it falls.
2.
Move the remaining guide to the
opposite side.
3.
Place the label guide back onto the
guide plate so that the locator tab is
inside the slot.
4.
Place the nut on the underside of the
guide plate so that the locator tab is
closest to the locator tab on the label
guide.
5.
Insert the Thumbscrew and turn
clockwise until it is tight.
Container Guide Instructions
1.
Move one of the guides to the outer
edges. Loosen one of the thumbscrews
until it is removed. Hold your hand
underneath guide plate to catch the
nut as it falls. Access to the underside
is only available on the far edge of either side.
2.
Move the remaining guide to the opposite side.
3.
Place the label guide back onto the guide plate so that the locator tab is inside the slot.
4.
Place the nut on the underside of the guide plate so that the locator tab is closest to the
locator tab on the label guide.
5.
Insert the Thumbscrew and turn clockwise until it is tight.
Thumbscrew
Guide Plate
Locator Tabs
Nut