![PrimaLuceLab SESTO SENSO 2 User Manual Download Page 16](http://html1.mh-extra.com/html/primalucelab/sesto-senso-2/sesto-senso-2_user-manual_1600920016.webp)
P r i m a L u c e L a b S p A
S E S T O S E N S O 2 u s e r m a n u a l
The SESTO SENSO 2 Virtual HandPad
allows you to control and use SESTO
SENSO 2 micro focuser without the need
of an EAGLE or of a computer.
On the top-right of your screen you can
find the SESTO SENSO 2 Virtual Hand-
Pad version. Then you can read the SE-
STO SENSO 2 firmware version, the ex-
ternal temperature (if you connected the
optional temperature sensor) and the in-
ternal motor temperature.
Below you can find the slider and the but-
ton to move the SESTO SENSO 2, toge-
ther with the step selector.
In the lower part you can find the 9 pro-
grammable buttons that allow you to save
up to 9 different focus positions, name
them and easily recall focus position with
just the push of a button.
Moving the SESTO SENSO 2 focuser with the SESTO SENSO 2 Virtual HandPad is very easy. You can do this in
different ways:
1. move the slider until you reach the desired position and tap on the GO button
2. make a double tap on the left field (where you can read the number in step of your focuser), write the number
you prefer with the virtual keyboard of your device and then press the GO button
3. select a value in the “Step offset” selector (from 100 to 2000 steps) and tap the < or > buttons to move the focu-
ser by the number you selected. Tap the << or >> buttons to move the focuser by 10 times the number you se-
lected.
In any moment, if you need to immediately stop the movement, press the
STOP button in the upper part.
In order to save a new position in the SESTO SENSO 2 Virtual HandPad,
first of all you have to move the SESTO SENSO 2 to a position where your
telescope is in perfect focus (you will need an optical accessory or a camera
in order to do this) and then follow this procedure:
p a g e 1 5
Virtual HandPad version
Settings
SESTO SENSO 2
controls
Presets buttons