P r i m a L u c e L a b S p A
S E S T O S E N S O 2 u s e r m a n u a l
You will see a new window. Move by hand the focuser
position to the innermost position of your focuser then:
1. press the “Init Calibration” button to start calibra-
tion
2. then press the “Set ZERO position” button in order
to set the 0 value of your calibration.
3. click the “Move out (!CAUTION!)” button: this will
start moving your focuser to the outer position. This
will move the focuser.
4. When your focuser is close to the outermost posi-
tion, click the “ Stop Motor and Set max limit” but-
ton.
Attention: please remember to stop the mo-
tor BEFORE it will reach the end of draw tube
travel or you may cause problems to the focu-
ser or to the SESTO SENSO 2 motor.
b) if you want to SESTO SENSO 2 on an SC type telescope with internal focuser and microfocuser, please select
“SCT Telescope with Microfocuser”.
You will see a new window. please turn the coarse
knob of the original focuser clockwise until it stops.
Then please click on NEXT button.
Now install SESTO SENSO 2 on the microfocuser of
your telescope. When SESTO SENSO 2 is installed,
press NEXT button.
p a g e 1 0