Stop

On

Set             10 hours later

(Auto-off Operation)

The TIMER OFF feature is useful when you want 
the unit to turn off automatically after you go to bed. 
The heat pump will stop automatically at the set 
time.

To stop the heat pump in 10 hours. 
1. Press the TIMER OFF button, the last setting of 
    stopping operation time and the signal "HOUR" will 
    show on the display area.
2. Press the TIMER OFF button to display "10" on 
    the TIMER OFF display of the remote controller.
3. Wait for 3 seconds and the TIMER OFF indicator 
    stops flashing and this function is activated. The 
    digital display area will show the temperature 
    again.

TIMER OFF

Example:

On

Stop

2 hours later
after setting

Set

To stop the heat pump 2 hours after setting 
and start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to
   display 2.0 HOUR on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to 
    display 10 HOUR on the TIMER ON display .
5. Wait for the remote control to display
    the setting temperature.

TIMER OFF 

 TIMER ON

(On 

 Stop 

 Start operation)

This feature is useful when you want to stop the 
heat pumpr after you go to bed, and start it again in 
the morning when you wake up or when you return 
home.

Example:

COMBINED TIMER 

(Setting both ON and OFF timers simultaneously)

Start

10 hours later
after setting

TIMER

HOUR

OFF

TIMER

HOUR

ON

OFF

Example:

TIMER ON 

 TIMER OFF

(Off 

 Start 

 Stop operation)

This feature is useful when you want to start 
the heat pump before you wake up and 
stop it after you leave the house.

To start the heat pump 2 hours after 
setting, and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again  to 
    display 2.0 HOUR on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to 
    display 5.0 HOUR on the TIMER OFF display .
5. Wait for the remote control to display
    the setting temperature.

Off

Stop

Start

2 hours later
after setting

5 hours later
after setting

Set

TIMER

HOUR

ON

OFF

Summary of Contents for PFCM123HX

Page 1: ...t pump Please read this owner s manual carefully before using your heat pump 202055091446 The design and specifications are subject to change without prior notice for product improvement Consult with...

Page 2: ...other electrical appliances react to the remote controller either move these appliances or consult your local dealer The remote controller is powed by two dry batteries R03 LR03X2 housed in the rear p...

Page 3: ...t can maintain the most comfortable temperature and save energy This function is available on COOL HEAT orAUTO mode only SWING V Button Used to stop or start horizontal louver move ment and set the de...

Page 4: ...ove are accomplished by the indoor unit if the indoor unit has no this feature there is no corresponding operation happened when press the relative button on the remote controller Please do not select...

Page 5: ...starting the unit CAUTION How to use the buttons 2 Before you start operating the heat pump set the clock of the remote controller using the proce dures given in this section The clock panel on the r...

Page 6: ...tting temperature on the remote controller 2 In the Auto mode you can not switch the fan speed It has already been automatically controlled 3 If the Auto mode is not comfortable for you the desired mo...

Page 7: ...inutes increments up to 10 hours then at 1 hour increments up to 24 hours 3 After setting the TIMER OFF there will be a one half second delay before the remote controller transmits the signal to the h...

Page 8: ...Press the TIMER ON button again to display 10 HOUR on the TIMER ON display 5 Wait for the remote control to display the setting temperature TIMER OFF TIMER ON On Stop Start operation This feature is...

Reviews: