Timer operation

press the TIMER ON button can set the auto-on 
time of the unit. And press the TIMER OFF button 
can set the auto-off time of the unit.

1. Press the TIMER ON button. The remote 
    controller shows TIMER ON, the last Auto-on 
    setting time and the signal "HOUR" will be shown 
    on the LCD display area. Now it is ready to reset 
    the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
    Auto-on time. Each time you press the button, 
    the time increases in 30 minutes increments, up 
    to 10 hours, then at 1 hour increments up to 24 
    hours. 
3. After setting the TIMER ON ,there will be a one-
    half second delay before the remote controller 
    transmits the signal to the heat pump. Then,
    after approximately another 2 seconds, the 
    signal "HOUR" will disappear and the set temper-
    ature will re-appear on the LCD display window.

 To set the Auto-on time.

To set the Auto-off time.

1. Press the TIMER OFF button. The remote 
    controller shows TIMER OFF, the last Auto-off 
    setting time and the signal "HOUR" will be shown 
    on the LCD display area. Now it is ready to 
    reset the Auto-off time to START the operation.
2. Push the TIMER OFF button again to set desired
    Auto-off time. Each time you press the button, 
    the time increases in 30 minutes increments, up
    to 10 hours, then at 1 hour increments up to 24 
    hours. 
3. After setting the TIMER OFF ,there will be a one-
    half second delay before the remote controller 
    transmits the signal to the heat pump. Then,
    after approximately another 2 seconds, the 
    signal "HOUR" will disappear and the set temper-
    ature will re-appear on the LCD display window.

   The effective operation time set by the remote controller for the timer 
   function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 
   3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13,
   14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.

IMPORTANT

Example of Timer setting

Start

Off

6 hours later

(Auto-on Operation)

The TIMER ON feature is useful when you want 
the unit to turn on automatically before say when 
you return home. The heat pump will automa-
tically start operating at the set time.

To start the heat pump in 6 hours.
1. Press the TIMER ON button, the last setting of 
    starting operation time and the signal "HOUR" will 
    show  on the display area.
2. Press the TIMER ON button to display "6.0" on
    the TIMER ON display of the remote controller.
3. Wait for 3 seconds and the TIMER ON indicator 
    stops flashing and this function is activated. The
    digital display area will show the tempera ture 
    again.

TIMER ON

Example:

Set

MODE

FAN SPEED

SWING V

SLEEP

TIMER ON

TIMER OFF

CLOCK

RESET  LOCK

AUTO

COOL

DRY

HEAT

FAN

TEMP.

SET

CLOCK

TIMER

HOUR

ON

OFF

M

TIMER

HOUR

ON

SWING H

SELF CLEAN

TURBO

LED

I FEEL

Summary of Contents for PFCM123HX

Page 1: ...t pump Please read this owner s manual carefully before using your heat pump 202055091446 The design and specifications are subject to change without prior notice for product improvement Consult with...

Page 2: ...other electrical appliances react to the remote controller either move these appliances or consult your local dealer The remote controller is powed by two dry batteries R03 LR03X2 housed in the rear p...

Page 3: ...t can maintain the most comfortable temperature and save energy This function is available on COOL HEAT orAUTO mode only SWING V Button Used to stop or start horizontal louver move ment and set the de...

Page 4: ...ove are accomplished by the indoor unit if the indoor unit has no this feature there is no corresponding operation happened when press the relative button on the remote controller Please do not select...

Page 5: ...starting the unit CAUTION How to use the buttons 2 Before you start operating the heat pump set the clock of the remote controller using the proce dures given in this section The clock panel on the r...

Page 6: ...tting temperature on the remote controller 2 In the Auto mode you can not switch the fan speed It has already been automatically controlled 3 If the Auto mode is not comfortable for you the desired mo...

Page 7: ...inutes increments up to 10 hours then at 1 hour increments up to 24 hours 3 After setting the TIMER OFF there will be a one half second delay before the remote controller transmits the signal to the h...

Page 8: ...Press the TIMER ON button again to display 10 HOUR on the TIMER ON display 5 Wait for the remote control to display the setting temperature TIMER OFF TIMER ON On Stop Start operation This feature is...

Reviews: