Price Industries Limited HOLYOAKE RAP Series Manual Download Page 7

5

www.holyoakepureair.com   |   Room AIR PuRIfIeR - manual

Room AiR PuRifieR

filter Replacement

Step 1: 

Gain access to the unit by removing one of the side 

access panels. 

Step 2: 

Remove filter by pulling on the frame to slide it out 

from under the brackets.

Step 3:

 Replace with a new filter.

NoTe:

 Recommended filter life for the MERV8 Pre-Filter is 4,000 

hours. Recommended filter life for the HEPA Filter is 20,000 
hours. Filter life is variable based on airflow set point, and air 
quality.

motor/Blower field Replacement 

Tools you will need to replace the motor/blower assembly in 
the field:

•  3/8 inch (9.5mm) nut driver bit.
•  Wiring diagram (located inside the control panel).
Recommended, but not required:

•  Right-angle attachment for drill.
•  12 inch (300mm) Drill bit extension. 

Removal Instructions:

1.  Disconnect all power to the unit.
2.  Remove access panel on either side of the unit. 
3.  Remove the screw attaching the power and control cables 

to the side of the blower. Once that is complete, unplug 
the power and control wires from the motor (Figure 1).

4.  Remove the 3/8 inch (9.5mm) bolts connecting the blower 

to the discharge plate.

THe PRiCe HoLYoAKe RAP    

SiDe ACCeSS PANeLS RemoVeD    

meRV8 AND HePA fiLTeR CHANGe    

SERVICE INSTRUCTIONS

Summary of Contents for HOLYOAKE RAP Series

Page 1: ...v001 Issue Date 12 08 21 2021 Price Industries Limited All rights reserved MANUAL INSTALLATION SERVICE Room Air Purifier RAP Series...

Page 2: ...ve These Instructions 1 Before You Start 1 Introduction 2 Installation Instructions Airflow Balancing 3 Service Instructions Filter Replacement 4 Motor Blower Field Replacement 4 Troubleshooting Troub...

Page 3: ...ent in the unit s external environment Before You Start Shipping Information Inspect all cartons and boxes for flaws and shipping damages If anything is discovered to be damaged contact the shipping c...

Page 4: ...ternal fan to draw air into the return through a HEPA filter and circulates the air back into the space through a grille With the fan continually running the air in your space is consistently filtered...

Page 5: ...with a slotted control screwdriver NOTE This potentiometer has voltage output for multi meter reading This is not required for setting airflow but can be utilised The potentiometers voltage range is...

Page 6: ...m requirements based on a 2 7m ceiling height can be seen below ACH Area m l s 2 48 72 66 99 97 146 132 198 163 245 197 296 3 32 72 44 99 65 146 88 198 108 243 132 297 4 24 72 33 99 48 144 66 198 81 2...

Page 7: ...cement Tools you will need to replace the motor blower assembly in the field 3 8 inch 9 5mm nut driver bit Wiring diagram located inside the control panel Recommended but not required Right angle atta...

Page 8: ...and 2 Rotate the blower into position so the top two holes line up Insert the bolts and hand tighten them in place 3 Use the 3 8 inch 9 5mm nut driver to tighten them 4 Plug the control and power wire...

Page 9: ...locity remains low High Air Velocity 1 Adjust variable speed control for lower blower output Motor Will Not Run 1 Check that motor has power at correct voltage 2 Check that the speed controller has po...