Introduction

Use this Quick Start Guide to quickly set up and understand the major 

components of the 

SmartXcan Mobile Pedestal

. It is critical to review these 

materials to ensure proper usage of the device. 

For further details, refer to the 

SmartXcan User Manual

.

Environmental Conditions

The SmartXcan requires specific environmental conditions for accurate 

temperature readings. Use in a space with controlled environmental 

conditions.

 

+

Ideal 64 - 75°F / 18 - 24°C 

 

+

Relative non-condensing humidity 10-75%

 

+

Do not place next to a heat source

 

+

The thermal image sensor should not be aimed at 

any other temperature source such as a incandescent 

light source, radiator, or A/C system

 

+

Do not point at the sun or open sky

Acclimation (Warmup) Period

The Unit requires one minute to start up 

and an estimated acclimation 

period of 15 minutes. This acclimation period allows the temperature 

scanning instrumentation to neutralize to the environment. The SmartXcan is 

set to allow temperature scans before the acclimation period is completed, 

but temperature accuracy can be affected. 

If the unit is moved after the initial acclimation period, the device should be 

allowed to re-acclimate for at least 15 minutes before performing additional 

temperature measurements. 

SmartXcan Mobile Pedestal

Accessories

Power Cable (IEC C13)

Varies based on country of use

Battery, 14.8V 98Wh

See Batteries Spec on page 7.  

Battery Charger, Travel Verison

See User Manual for charging 

information.  

Battery Compartment Key (x2)

Indicator Light

Temperature Scanner

Summary of Contents for SmartXcan

Page 1: ...PRG SmartXcan Quick Start Guide VERSION 1 0 WWW PRG COM...

Page 2: ...s manual are trademarks or registered trademarks of their respective companies This manual is for informational use only and is subject to change without notice Please check www prg com for the latest...

Page 3: ...ture source such as a incandescent light source radiator or A C system Do not point at the sun or open sky Acclimation Warmup Period The Unit requires one minute to start up and an estimated acclimati...

Page 4: ...7 9 C Measurement successful LED ring red 6 of 8 LEDs light up Slightly increased body temperature 100 4 101 0 F 38 0 38 3 C Measurement successful LED ring red 7 of 8 LEDs light up Increased body tem...

Page 5: ...l operate as is without any additional network or computer connections This is the most simple and common operating mode Networked Optionally the user may choose to connect the device to a single comp...

Page 6: ...e Position face about 12 inches from the scanner 2 Identify the center of the temperature scanner The ring will illuminate green once in the measurement zone 3 Measurement Acceptable Measurement Not A...

Page 7: ...Specs Mains 100 240V 10 50 60 Hz 0 5A Max PoE 37 44VDC 0 35A PoE Type 1 See User Manual for connection information Battery 14 8VDC 1 0A Operating Ranges 18 C to 24 C 10 75 non condensing humidity IEC...

Page 8: ...l be placed on the apparatus Medical Disclosure This manual is not intended to define any policy or procedures The SmartXcan is not a medical thermometer It shall not be utilized as a substitute for a...

Reviews: