Appendix B
– Troubleshooting Guide for Multiplex Vehicles
2
Problem/Symptom
Probable Causes
Actions
Many secondary functions
(not essential for driving)
not functioning (interior
lighting,
driver's
area
lighting, wiper speed 2
and intermittent).
Marker
lights
and
clearance
lights
are
turned ON when setting
ignition to the ON position.
The MCM module does not
receive 24 V power.
The CAN network is not
working. It could be caused
by a short on the network, an
open circuit, a problem with
the MCM or the MCM being
disconnected
from
the
network.
1.
Check / reset circuit breaker CB6.
Check / replace fuse F1
2.
Operate in limp-home mode by
starting the vehicle from the engine
compartment (REAR START). All
functions essential to drive are
available
To close and lock the door, pull the door
manually up to its closed position and it
will lock by itself. The door opening button
is still functioning
No temperature control in
the cabin area.
Cabin temperature display
indicates two dashes "--"
Problem with the temperature
sensor
located
in
the
evaporator compartment air
intake or the sensor wiring.
Manually control the temperature by
playing with the cabin (passenger) set
point. Set above 22°C (72°F) to heat and
below 22° C (72°F) to cool.
Entrance door does not
open nor close using the
control buttons
Defroster
fan
not
functioning
Windshield
wipers
not
functioning in speed 1 or
intermittent
Module AE47 is not powered
or is faulty
1.
Check the SYSTEM DIAGNOSTIC
menu of Driver Information Display
(DID). Select FAULT DIAGNOSTIC
and ELECTRICAL SYSTEM. The
message “No Response ModA47,
Active” indicates a power problem on
the module. (A CAN network problem
would show the same message but
doesn't produce these symptoms).
2.
Check / reset circuit breaker CB1
3.
Check / replace fuse F45
4.
Probe gray connector on module to
see if it is powered.
5.
Use the air release valves near the
entrance door and in the front service
compartment to lock / unlock the door
Windshield
wipers
not
functioning in speed 1 or
intermittent
No power on R27
Check CB48 (VECF)
HVAC condenser fans not
functioning in speed 1
Circuit breaker CB5 tripped
Check / reset circuit breaker CB5
HVAC condenser fans not
functioning in speed 2
Circuit breaker CB5 tripped
Check / reset circuit breaker CB5
Check / replace fuse F135
Summary of Contents for X3-45 VIP 2017
Page 1: ...Owner S MANUAL X3 45 VIP...
Page 2: ......
Page 3: ...COACH MANUFACTURER OWNER S MANUAL X3 45 VIP PA1625 Rev 2 November 2017...
Page 8: ...Foreword iv...
Page 10: ......
Page 14: ......
Page 34: ......
Page 172: ...Technical Information 9 2 VEHICLE IDENTIFICATION NUMBER VIN 12 VEHICLE FINAL RECORD 13...
Page 173: ...Technical Information 9 3 OVERALL DIMENSIONS...
Page 174: ...Technical Information 9 4 OVERALL DIMENSIONS...
Page 184: ...Technical Information 9 14...
Page 186: ......
Page 190: ......
Page 211: ......
Page 212: ......