Other Features
5-34
PROBLEM
CAUSE
CORRECTIVE ACTION
The slide-out
does not
extend
A. The parking brake is not seen by the controller
as being applied;
B. Not enough air pressure in the accessory air
tank to permit proper operation of the vacuum
generator;
C. Faulty vacuum generator, connection to the
vacuum generator open, seal deflating valve
solenoid open circuit;
D. I/O-B module output defective, regulated 5-volt
supply to sensors shorted to ground, “out limit”
sensor shorted to ground, connection to the
motor negative relay solenoid open circuit;
A. Make sure the parking brake is
applied. Confirm parking brake
application with the parking brake
light on the telltale panel.
B. Run the engine at fast idle a few
minutes to increase air pressure in
the accessory air tank and try again.
C. Turn the relieving shut-off valve
handle clockwise to deflate the
inflatable seal, disconnect the
pressure transducer. Do not forget to
reconnect the pressure transducer
and to close the relieving shut-off
valve. Failure to do so could damage
the seal and lead to water infiltration;
D. Operate the slide-out with the manual
override procedures.
The slide-out
does not
retract
A. Not enough air pressure in the accessory air
tank to permit proper operation of the vacuum
generator;
B. Faulty vacuum generator, connection to the
vacuum generator open, seal deflating valve
solenoid open circuit;
C. I/O-B module output defective, “in limit” sensor
shorted to ground, connection to the motor
positive relay solenoid open circuit;
A. Run the engine at fast idle a few
minutes to increase air pressure in
the accessory air tank and try again.
B. Turn the relieving shut-off valve
handle clockwise to deflate the
inflatable seal, disconnect the
pressure transducer. CAUTION, do
not forget to reconnect the pressure
transducer and to close the relieving
shut-off valve. Failure to do so could
damage the seal and lead to water
infiltration;
C. Operate the slide-out with the manual
override procedures.
When
extending, the
slide-out stops
after having
extended by 1
inch
The security pin valve solenoid circuit is shorted to
(+) 24-volt and the pin remains engaged;
Disconnect air supply from the safety pin
cylinder;
Transmission
DRIVE range
or REVERSE
cannot be
selected (the
slide-out
telltale light is
illuminating).
A. Slide-out not in full "in" position;
B. Faulty “in limit” sensor. The slide-out is
retracted but the controller doesn’t not see it
as retracted.
A. Retract slide-out.
B. Confirm that all slide-outs are
retracted. On the slide-out control
panel, disconnect the 5 pins green
connector on the I/O-B module to
disable the transmission inhibit.
CAUTION, this is a temporary
measure, the vehicle must be
serviced as soon as possible.
Summary of Contents for X3-45 VIP 2017
Page 1: ...Owner S MANUAL X3 45 VIP...
Page 2: ......
Page 3: ...COACH MANUFACTURER OWNER S MANUAL X3 45 VIP PA1625 Rev 2 November 2017...
Page 8: ...Foreword iv...
Page 10: ......
Page 14: ......
Page 34: ......
Page 172: ...Technical Information 9 2 VEHICLE IDENTIFICATION NUMBER VIN 12 VEHICLE FINAL RECORD 13...
Page 173: ...Technical Information 9 3 OVERALL DIMENSIONS...
Page 174: ...Technical Information 9 4 OVERALL DIMENSIONS...
Page 184: ...Technical Information 9 14...
Page 186: ......
Page 190: ......
Page 211: ......
Page 212: ......