XL2 SLIDE-OUT SERVICE MANUAL
17.3 MOTOR CONTROLLER
The motor controller has 4 LED to show the controller activity and indicate errors (figure 36). The error
LED flashes once every 2 seconds when the controller is in operation. When retracting the slide-out, the
"Motor In" LED comes on, and when extending the slide-out, the "Motor Out" LED comes on. When the
motor is in motion activity, the error LED is disabled. In that state, if a communication error is detected,
the motor is stopped 2 seconds after the detection.
SIGNAL
PROBLEM
CAUSE
CORRECTIVE ACTION
Error LED fast
flashing: one
flash every
second
(1 Hz)
Communication
error
A. Bad electrical connection with the
logic controller.
B. Logic controller turned off or
defective;
A. Check the communication cable
between the two controllers.
B. Check the logic controller condition
(section 17.2).
Error LED: one
long flash every
three seconds
2.9 sec ON
.1 sec OFF
Communication
error
A. Opened connection to motor;
B. Defective power transistor.
C. Safety controller defective or bad
electrical connections.
A. Check communication cable and motor
power supply wiring.
B. Change the motor controller (section
C. Check the safety controller and the
electrical connections conditions.
Change the safety controller if
necessary (refer to section 13.3.7).
Reset the power on the controllers.
Overcurrent LED
comes on and
stays on only one
second.
Software
protection
activated
Software overcurrent detected
(threshold at 34 A):
A. Excessive weight;
B. Obstruction to the slide-out
movement;
C. Mechanical component failure;
D. Motor controller defective;
A. Reduce the weight in the slide-out.
B. Remove any obstacle that may obstruct
slide-out movement.
C. Check the mechanical component
condition.
D. Change the motor controller (section
Overcurrent LED
and error LED
come on and
stay on only one
second.
Hardware
protection
activated
Hardware overcurrent detected
(threshold at 40 A):
A. Excessive weight;
B. Obstruction to the slide-out
movement;
C. Mechanical component failure;
D. Motor controller defective;
Overheat detected (threshold at 120°C):
E. Controller internal temperature over
120°C (248°F).
A. Reduce the weight in the slide-out.
B. Remove any obstacle that may obstruct
slide-out movement.
C. Check the slide-out driving component
condition.
D. Change the motor controller
(section13.3.1).
E. Check the controller compartment for
abnormal temperature.
Reset the power on the controllers.
R3
41
May 3, 2002