XL2 SLIDE-OUT SERVICE MANUAL
FIGURE
14
:
PIN RECEPTACLE INSTALLATION
5. Remove the pin receptacle.
FIGURE
15
:
PIN RECEPTACLE ON GLASS
6. Remove the old sealant. Clean the panel or
glass inner contact surfaces with alcohol.
7. Apply black Sika 222 UV or equivalent
product on the glass surface contact with the
pin receptacle (figure 15), and black Sika
221 or equivalent product on the panel
surface contact with the pin receptacle
(figure 16).
8. Install a pin receptacle on the threaded rods.
Put the plastic cap back on.
9. One by one, replace the threaded rods with
the washers and the screws.
FIGURE
16
:
PIN RECEPTACLE ON STAINLESS STEEL PANELS
10. Clean excess sealant with alcohol.
11. Readjust the locking pins as described in
section 2.2 (if needed).
3. ROOF REINFORCING ROD
Caution: The front slide-out roof reinforcing rod
may have to be adjusted after a load variation
inside the vehicle or on the top of the vehicle.
Caution: Always lock the turnbuckle using the
jam nut to prevent loosening.
The roof reinforcing rod is located on the upper
horizontal member of the front slide-out and is
welded on the roof arches (figure 17).
FIGURE
17
:
FRONT SLIDE
-
OUT ROOF REINFORCING ROD
R3
13
May 3, 2002