3
Technical specifications
ENGLISH
Power cord grips: Type “Y”.
Build quality: Basic insulation.
Thermal insulation winding: Class H
Power Requirements
29961
Code
Description
SOIN-101MP
Rated Input Capacity
Input Voltage
Current Range
20 A - 100 A
Power Factor
Cos 0.73
Inverter Welder
127 V / 60 Hz
1/16” - 1/8”
3.8 kVA
Electrode
IP21S
IP Grade
8.34” x 3.4” x 5.3”
Dimension
60%
6 minutes’ work per 4 minutes’ rest.
Output values specified are with a 68 ºF Temperatures higher than the work cycle may be reduced.
Rated Duty Cycle
Insulation
Class I
12 AWG x 2C with 221 °F insulation temperature
Conductors
5 lb
Weight
Open Circuit Voltage
69 V c.c.
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
If faults or breakdowns happen. Ground connection offers a
trajectory with minimum resistance for electric power. It reduces the risk of electric
shock. This tool is built with a power cable with an earth conductor and a plug with
ground connection. The plug shall be connected into a power outlet installed and
grounded according to all local codes.
Do not modify the plug supplied. If the plug cannot be fitted
to the socket, have a qualified electrician to install the suitable socket.
• When using the welder together with more tools using the same ground connect those in parallel, never connect a
series.
• The gauge of the ground conductor cable shall not be of a smaller gauge than the power supply cable.
• Connection to the power supply shall only be carried out by a professional electrician.
• Double check the input connection voltage stipulated in the welder nameplate matches the power
supply voltage.
• The power supply cord shall meet the following requisites:
CAUTION
CAUTION
CAUTION
* The current for fuse fusion is double of its rated current.
Switch
Fuse (Work Rated Current)
Electric Wire
30 A
30 A (*)
2.5 mm
2
• If extensions between the welder and the work piece
are needed, the soldering cable gauge shall be increased
to keep the welder energy output with a potential drop
not higher than 4 V
CAUTION
WARNING
WARNING