                            • Do not touch the power plug with wet hands. Always disconnect the plug and do not pull off 

the power cable. Do not use the power cable to lift, carry or hold the pump in any way. Do not use the cable for 

uses different to the specified use. Do not pull the cable while the pump is running. It can get damaged and cause 

an electric shock.

• This line of submersible pumps is designed to pump 

fresh and clean water from springs, wells and other water 

reservoirs, as well as water reservoirs or irrigation systems 

with clean water and solid particles up to 0.2”

                           • To prevent blockages, do not operate 

the pump with waters containing larger particles.

                             • Do not pump corrosive, combustible 

or explosive substances (gasoline, petroleum, thinner 

nitrate) grease, oil, salt and sewer water.

                           • The pump is not designed to operate 

continuously. Cannot be used replacing continuous use 

fixed pumps. The useful life of the pump will be shorter in 

relation to the use.

                          • The pump is not adequate for 

commercial use, nor for permanent circulation and filtering 

systems, or to be used with liquids containing abrasive 

materials, or soil, sand, mud, or clay mixes. Any of those 

uses is considered inadequate and can damage the pump. 

• The temperature of the liquids shall not exceed 95 °F, nor 

as cold as there is the possibility of freezing.

                           • Prevent the pump from running dry.

5

CAUTION

CAUTION

CAUTION

CAUTION

Appropriate Use of the Pump

                            • Do not use the pump in the nearness 

of areas where explosives, flammable liquids or gases are 

kept. 

                          • Any change or modification to the 

pump and the use of non-approved spare parts could 

damage the equipment and cause accidents.

                            • To prevent accidents, it is forbidden to 

wash things, swim or bathe into the water container where 

the pump is running.

                          • Always verify the pump before each use, 

(especially the power cable and its plug). A damaged 

pump shall not be used. Go to a                                  

Authorized Service Center to have it fixed.

                           • Any type of repairs shall be carried out 

by a certified technician. If repairs are carried out in a faulty 

manner there is danger of liquid entering into the electric 

components.

                             • It is not advisable that people 

(including children), with reduced physical, sensorial or 

mental capacities, as well as people with no experience or 

knowledge, use the pump except if they are supervised by 

people responsible for their safety or having received 

previous instructions for the pump’s use.

                          • Children shall be supervised to ascertain 

they do not play with the pump. Strict supervision is 

required when people with reduced capacities or children 

use any power device or are close to them.

WARNING

CAUTION

WARNING

CAUTION

CAUTION

CAUTION

WARNING

WARNING

ENGLISH

Safety Warnings for

Submersible Pumps

WARNING

It is recommended to tie a rope to the carrying handle to lift the pump.

Summary of Contents for 27197

Page 1: ...Manual Submersible Pump Model Code BOS 1LPP Applies for 27197 For CLEAN Water CAUTION Read this manual thoroughly before using the tool INGLÉS ESPAÑOL ...

Page 2: ...anty 3 3 4 5 6 7 8 8 9 10 11 12 Contents CAUTION Keep this manual for future references The illustrations in this manual are for reference only They might be different from the real tool To gain the best performance of the tool prolong the duty life make the Warranty valid if necessary and to avoid hazards of fatal injuries please read and understand this Manual before using the tool ENGLISH BOS 1...

Page 3: ...gned for operating outdoors and reduce the risk of electric shock WARNING All the cabling power connections and the ground connection of the system shall be in compliance with the Mexican Official Standard NOM 001 SEDE 2012 Electrical Installations Use or with the local codes and municipal by laws WARNING 5 A Current 27197 1 Hp Submersible Pump for Clean Water Code Description Voltage and Frequenc...

Page 4: ...ed situations Dress properly Do not wear loose clothing or jewelry Keep hair clothes and gloves away from the moving parts Loose clothes or long hair may get caught in moving parts If you have dust extraction and recollection devices connected onto the tool inspect their connections and use them correctly Using these devices reduce dust related risks Power Tools Use and Care Do not force the tool ...

Page 5: ...y of freezing Prevent the pump from running dry 5 CAUTION CAUTION CAUTION CAUTION Appropriate Use of the Pump Do not use the pump in the nearness of areas where explosives flammable liquids or gases are kept Any change or modification to the pump and the use of non approved spare parts could damage the equipment and cause accidents To prevent accidents it is forbidden to wash things swim or bathe ...

Page 6: ...peed see the manufacturer s nameplate Do not entangle tighten or run over the power cable Protect it from sharp edges oil or heat Do not use extension cables with a lower gauge than the power cable gauge In the event the power cable is damaged disconnect the pump from the power supply immediately Never run a pump if the power cable is damaged Disconnect the plug from the power supply before removi...

Page 7: ...d the rope and immerse the pump Never use the power cable or the float switch to carry or hang the pump Tie the other end of the rope to some fixed point to support the pump no deeper than the maximum depth marked for each model under the water surface and no less than 20 away from the bottom to prevent mud particles algae or residue blocking the pump Double check there are no obstacles so that th...

Page 8: ...p to automatically shut off you may set the switch cable through the transport handle D so that the float cannot plunge down and shut off the pump When controlling the float switch manually keep on supervising the pump s functioning and prevent the water level to be so low it will make the pump operating dry Float Switch CAUTION Maintenance Inspect regularly all the mounting screws and double chec...

Page 9: ... base Take the pump to a Authorized Service Center Disconnect the main plug Clean the pump and the axis DO NOT try to pump dirty water Verify water temperature is not over 95 F The pump cannot be turned on or it suddenly stops while operating There is no flow The pump does not turn off Insufficient flow The pump shuts off after a short period working No power The float is not changing its position...

Page 10: ...10 ENGLISH Notes ...

Page 11: ...TE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZUÑIGA JAL TEL 33 3606 5285 AL 90 FIX FERRETERÍAS AV PASEO DE LA REPÚBLICA 3140 A COL EX HACIENDA DE LA HUERTA C P 58050 MORELIA MICH TEL 443 334 6858 FIX FERRETERÍAS CAPITÁN ANZURES 95 ESQ JOSÉ PERD...

Page 12: ...sonnel not authorized by Truper To make the warranty valid present the product stamped policy or invoice or receipt or voucher in the establishment where you bought it or in Corregidora 22 Centro Cuauhtémoc CDMX 06060 where you can also purchase parts components consumables and accessories It includes the costs of transportation of the product that derive from its fulfillment of its service networ...

Page 13: ... o reparado por personal no autorizado por Truper Para hacer efectiva la garantía presente el producto póliza sellada o factura o recibo o comprobante en el establecimiento donde lo compró o en Corregidora 22 Centro Cuauhtémoc CDMX 06060 donde también podrá adquirir partes componentes consumibles y accesorios Incluye los gastos de transportación del producto que deriven de su cumplimiento de su re...

Page 14: ... 80 88 CENTRO DE SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZUÑIGA JAL TEL 33 3606 5285 AL 90 FIX FERRET...

Page 15: ...10 ESPAÑOL Notas ...

Page 16: ...n Lleve la bomba a un Centro de Servicio Autorizado Desconecte la clavija principal Limpie la bomba y el eje NO intente bombear agua sucia Verifique que la temperatura del agua no sobrepase los 35 C La bomba no enciende o se detiene de repente durante la operación No hay flujo La bomba no se apaga Flujo insuficiente La bomba se apaga después de un período corto de operación No hay energía eléctric...

Page 17: ...correr el cable del interruptor por el seguro del cable en el asa de transporte D para que el flotador no pueda bajar y apagar la bomba Cuando controle el interruptor de flotador de forma manual no deje de supervisar el funcionamiento de la bomba para evitar el nivel del agua baje tanto que la bomba llegue a operar en seco Interruptor de flotador ESPAÑOL ATENCIÓN Mantenimiento Inspeccione regularm...

Page 18: ...enga la cuerda y sumerja la bomba Jamás utilice el cable de alimentación o el interruptor de flotador para trasladar o colgar la bomba Amarre el otro extremo de la cuerda en algún punto para sostener la bomba a no más de 7 m debajo de la superficie del agua y a no menos de 50 cm del fondo para evitar que se tape con lodos partículas algas o residuos Asegúrese de que no haya obstáculos para que el ...

Page 19: ...el suministro eléctrico de inmediato Nunca use la bomba si el cable eléctrico está dañado Desconecte la clavija del suministro eléctrico antes de retirar la bomba del agua o dar servicio a la bomba Se debe desconectar la bomba cuando no esté en uso Antes de conectar la bomba al suministro eléctrico verifique que el interruptor flotador esté en posición de apagado ver página 8 sección Interruptor f...

Page 20: ...posibilidad de congelación Evite que la bomba trabaje en seco 5 ATENCIÓN ATENCIÓN ATENCIÓN ATENCIÓN Advertencias de Seguridad para uso de bombas sumergibles Uso adecuado de la bomba No use la bomba en áreas donde existan explosivos o cerca de líquidos inflamables o gases Cualquier cambio o modificación a la bomba y el uso de refacciones no aprobadas podría dañar el equipo y provocar accidentes Par...

Page 21: ...n asentados sobre el suelo y conserve el equilibrio en todo momento Esto permite un mejor control de la herramienta en situaciones inesperadas Vista adecuadamente No vista ropa suelta o joyas Mantenga su pelo su ropa y guantes alejados de las piezas en movimiento La ropa o el pelo suelto o las joyas pueden quedar atrapados en las piezas en movimiento En caso de contar con dispositivos de extracció...

Page 22: ... POR NINGÚN MOTIVO Utilice un adaptador temporal como se muestra en el ejemplo B y siempre conecte la oreja del conductor de tierra como se indica Al usar un cable de extensión asegúrese de usar el calibre suficiente para transportar la corriente que consumirá su herramienta Un cable de un calibre inferior ocasionará caídas de tensión en la línea teniendo como resultado pérdida de potencia y sobre...

Page 23: ...icio Autorizados Póliza de Garantía Guarde este instructivo para futuras referencias Los gráficos de este instructivo son para referencia pueden variar del aspecto real de la herramienta 3 3 4 5 6 7 8 8 9 10 11 12 BOS 1LPP Para poder sacar el máximo provecho de la herramienta alargar su vida útil hacer válida la garantía en caso de ser necesario y evitar riesgos o lesiones graves es fundamental le...

Page 24: ...Instructivo de Bomba sumergible Modelo Código Este instructivo es para Para agua LIMPIA Lea este instructivo por completo antes de usar la herramienta ATENCIÓN ESPAÑOL ENGLISH BOS 1LPP 27197 ...

Reviews: