BOS-1LPP
Technical Data
A
B
3
Power cord grips used in this product: Type “Y”.
Build quality: Basic insulation
Thermal insulation on motor winding: Class F
Power Requirements
The equipment shall be grounded while in use to prevent an electric shock.
• Connect plug into a properly grounded contact or outlet as shown in
example
A
. Not all contacts or outlets are properly grounded. If not sure,
contact with a certified electrician.
• If the outlet you want to use with the equipment has two poles (2 orifices),
FOR ANY REASON AT ALL DO NOT REMOVE OR ALTER THE PLUG’S EARTH
TERMINAL. Use a temporary adapter as shown in example
B
and always
connect the earth conductor’s lug as indicated.
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows
the right size to use depending on cable’s length and the ampere capability
shown in the tool’s nameplate. When in doubt use the next higher gauge.
WARNING
CAUTION
CAUTION
When operating power tools outdoors, use a grounded extension cable labeled
“For Outdoors Use”. These extensions are especially designed for operating outdoors and reduce the risk of
electric shock.
WARNING
All the cabling, power connections and the ground connection of the system shall be in
compliance with the
Mexican Official Standard
NOM-001-SEDE-2012, Electrical Installations (Use)
or with the local codes and municipal by-laws.
WARNING
5 A
Current
27197
1 Hp
Submersible Pump for Clean Water
Code
Description
Voltage and Frequency
Power
127 V
60 Hz
3450 RPM
Speed
22.9’
250 L/min
Flow Rate
Maximum Depth
27.8’
Power Cable
18 AWG x 3 C with 221 °F insulating temperature .
Class I
Conductors
Insulating
20 minutes of work per 15 minutes of rest Maximum 6 hours a day
Duty Cycle
IPX8
IP Grade
32.8’
Maximum Height / Maximum
Value of Total Gauged Height
ENGLISH
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
18 AWG
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
From 6 ft to 49 ft | Higher than 49 ft
Ampere
Capacity
Number of
Conductors
Extension Gauge