3.
If the voltage is still less than 7.5 Vdc after recharging, replace the battery.
To check the battery charge operation, use a discharged battery pack or a battery pack that has less than 50%
of the total power remaining when installed in the computer.
If the battery status indicator does not light up, remove the battery pack and let it return to room temperature.
Re-install the battery pack.
If the charge indicator still does not light up, replace the battery pack. If the charge indicator still does not light
up, replace the DC/DC charger board.
Touchpad Check
If the touchpad doesn’t work, do the following actions one at a time to correct the problem. Do not replace a
non-defective FRU:
1.
Reconnect the touchpad cables.
2.
Replace the touchpad.
3.
Replace the main board.
After you use the touchpad, the pointer drifts on the screen for a short time. This self-acting pointer movement
can occur when a slight, steady pressure is applied to the touchpad pointer. This symptom is not a hardware
problem. No service actions are necessary if the pointer movement stops in a short period of time.
1
4
5
2
3
6
7
TECHNICAL SERVICE MANUAL
Prestigio Nobile 157
85
Summary of Contents for NOBILE 157
Page 1: ...PRESTIGIO NOBILE 157 TECHNICAL SERVICE MANUAL ...
Page 57: ...TECHNICAL SERVICE MANUAL Prestigio Nobile 157 50 ...
Page 89: ...TECHNICAL SERVICE MANUAL Prestigio Nobile 157 82 ...
Page 107: ...Prestigio Nobile 157 Exploded Diagram TECHNICAL SERVICE MANUAL Prestigio Nobile 157 100 ...
Page 115: ...TECHNICAL SERVICE MANUAL Prestigio Nobile 157 108 ...
Page 121: ...TECHNICAL SERVICE MANUAL Prestigio Nobile 157 114 ...
Page 125: ...TECHNICAL SERVICE MANUAL Prestigio Nobile 157 118 ...
Page 126: ...www prestigio com ...