Index of PQA Diagnostic Error Code, Message
Error Code
Message
Action in Sequence
16XXX
Backup battery error
Backup battery
01XXX
CPU or main board error
Reload BIOS default setting.
Main Board
02XXX
Memory error
DIMM
Main Board
03XXX
Keyboard error
Reset Keyboard
Keyboard
Main Board
04XXX
Video error
Main Board
05XXX
Parallel Port error
Main Board
06XXX
Serial port or main board error
Main Board
07XXX
Diskette drive error
Diskette drive
Main Board
08XXX
Hard disk error
Reload BIOS default setting
Hard disk
Main Board
09XXX
CD-ROM error
Reset CD-ROM cable
CD-ROM drive
Main Board
10XXX
Co-processor error
Main Board
11XXX
Pointing device error
Reset Keyboard
Keyboard
Main Board
12XXX
Cache test error
Main Board