6. Mounting
Mounting the vacuum-overpressure safety valve
The mounting of the vacuum-overpressure safety valve is as follows:
Make sure there are no irregularities on the flange of the vacuum-overpressure safety valve other than the
placed components of the manufacturer. Loosen all the RVS nuts on the threaded ends. Place a rubber
gasket of the correct dimensions on de welding flange. Place the vacuum-overpressure safety valve on the
flange with the threaded ends through the holes in the welded flange. Tighten the nuts on the threaded ends.
Make sure that all the nuts are all tightened even. Make sure that the connection between the welded flange
and the valve is leak-proof. The valve is now company ready.
Mounting the vacuum safety valve
The mounting of the vacuum safety valve is as follows:
Make sure there are no irregularities on the flange of the vacuum safety valve other than the placed
components of the manufacturer. Place a rubber gasket on the welded flange. Place the vacuum safety
valve on the four holes on the welded flange. Place 4 M16 bolts through the holes and place 4 M16 nuts on
the bottom side. Make sure all the nuts are tightened even. Make sure that the connection between the
welded flange and the valve is leak-proof. The valve is now company ready.
Summary of Contents for FX PREVENT