background image

I. Disclaimers, Exclusions and Limitations of Liability 

PLEASE  READ  AND  NOTE  PRESIDIUM  WARRANTY 
TERMS  AND  CONDITIONS  as  stated  in  the  warranty 
card.  Presidium  warranty  for  its  testers  are  subject  to 
proper use by its users in accordance with all the terms 
and conditions as stated in the relevant user handbook 
and shall cover only manufacturing defects. 

Due to continuous product improvement, Presidium 
reserves  the  right  to  revise  all  documents  including  the 
right to make changes to the handbook without notice and 
without obligation to notify any person of such revisions 
or changes. Users are advised to check Presidium’s 
website http://www.presidium.com.sg/ from time to time.

Presidium  shall  not  be  responsible  for  any  damage  or 
loss resulting from the use of this tester or handbook, and 
under no circumstances shall Presidium, its manufacturer 
or any of its subsidiaries, licensors, distributors, resellers, 
servants and/or agents be liable for any direct or indirect 
damages, resulting from the use of this tester.

TO  THE  MAXIMUM  EXTENT  PERMITTED  BY
APPLICABLE  LAW,  under  no  circumstances  shall 
Presidium,  its  manufacturer  or  any  of  its  subsidiaries, 
licensors,  distributors,  resellers,  servants  and/or 
agents  be  responsible  for  any  special,  incidental, 
consequential  or  indirect  damages  howsoever  caused. 

The  tester  or  Presidium  Carat  Scale  (PCS-100n)  
referred  to  in  this  handbook  is  provided  and/or  sold  on 
an “as is” basis. Except as required by applicable law, no 
warranties  of  any  kind,  either  expressed  or  implied, 
including,  but  not  limited  to,  the  implied  warranties  of

merchantability and fitness for a particular purpose.

Summary of Contents for PCS-100n

Page 1: ...ur Presidium Carat Scale pg 06 IV IMPORTANT NOTICE pg 08 1 GETTING STARTED with your Presidium Carat Scale pg 09 2 PERFORMING A TEST with your Presidium Carat Scale pg 12 3 TROUBLESHOOTING your Presid...

Page 2: ...sible for any damage or loss resulting from the use of this tester or handbook and under no circumstances shall Presidium its manufacturer or any of its subsidiaries licensors distributors resellers s...

Page 3: ...to know about how to use your scale accurately and take care of it in line with its requirements Please read these instructions carefully and keep them handy for future reference This book also contai...

Page 4: ...a micro controller inside the scale The Presidium Carat Scale features the following Four conversion options gram carat ounce grain Three trays for different uses Product specifications Weighing capa...

Page 5: ...1 Display Window 2 Calibration Button 3 Mode Button 4 Tray 5 Transparent Lid 6 Opening Recess 7 Battery Cover 8 Reference Load 20g 9 USB Inlet 10 Vessel 11 TARE Button 12 ON OFF Button...

Page 6: ...o not use store or expose the scale in cold areas When the tester returns to its normal temperature moisture can form inside the tester and damage electronic circuit boards Do not attempt to open the...

Page 7: ...er end directly into a suitable electrical outlet Please ensure that only the adaptor supplied by Presidium is used Fig 1 1 If batteries are used 4 x AAA batteries take note of the positive and negati...

Page 8: ...ransparent lid Place the tray on the weighing arm then close the lid Fig 1 3 Press the ON OFF button Fig 1 4 to turn on the scale Fig 1 3 Fig 1 4 Fig 1 5 All segments on the Display should blink three...

Page 9: ...ced on the weighing tray Fig 1 6 Close the transparent lid CAL will become stable and after a few seconds 20 000g will appear this signifies the completion of calibration Fig 1 7 The unit is now ready...

Page 10: ...the word READY appears The result will be displayed immediately on the LCD For accurate reading take the reading only after the word READY appears Fig 2 2 Fig 2 1 Fig 2 2 Fig 2 3 For conversion betwe...

Page 11: ...arm press TARE to offset the weight of the vessel Tips for using your Presidium Carat Scale Keep the transparent lid closed when the scale is in operation It is advisable to take multiple readings if...

Page 12: ...repeated Error sign appears during calibration The calibration weight was placed onto the tray before the CAL started blinking Err LO sign appears during calibration The calibration weight is below t...

Page 13: ...e leak or damage the scale Batteries should be removed when the instrument is expected to be stored for an extended period of time Your scale is a product of extensive design and craftsmanship and sho...

Reviews: