Presenza QR001 Installation Manual And User'S Manual Download Page 18

 18
 

Care and Cleaning

RANGE HOOD

WARNING: 

Failure to maintain basic standards of care 

and cleaning of the range hood will increase the risk of fire.

The range hood should be cleaned (regularly internally and externally) to preserve its appearance and performance. 

Do:

Do Not:

 

- Always clean in the direction of the grain (original  

polish lines) .

 

- Clean the range hood periodically with hot, soapy 

water and a clean cotton cloth . 

 

- Always rinse well with clean water two or three 

times after cleaning . Wipe completely dry with a 
soft non-abrasive cloth.

 

- After cleaning, you may polish with a non-abrasive 

stainless steel polish or cleaner. Always rub lightly 
and with the grain .

 

- Ensure that the venting system is free of debris, if 

you have one .

 

- Do not use corrosive or abrasive detergents, steel 

wool, or scouring pads . These will scratch and 
damage the stainless steel surface .

 

- Do not use corrosive or abrasive detergents, or any 

products containing chloride, fluoride, iodide, or 
bromide on this product, as they will deteriorate 
the surface rapidly .

 

- Do not allow cleaning compounds, salt solutions, 

disinfectants, or bleaches to remain in contact with 
the product for extended periods of time.

 

- Do not allow deposits to remain for long periods 

of time on the range hood . Rinse with water 
immediately and wipe dry with a clean cloth .

 

- Do not let plaster dust or any other construction 

residue enter the hood . During construction or 
renovation, cover the hood .

 - Combustible products used for cleaning such as 

acetone, alcohol, ether, or benzol are highly explosive 
and should never be used close to a range or stove .

FILTERS / BAFFLE NETS

The filter fitted by the factory is intended to filter out residue and grease from cooking. You do not need to replace them on a regular basis, 
but you should keep them clean .

Do:

Do Not:

 

- Clean the filters / baffle nets once a month using 

non-abrasive detergents, either by hand or in 
the dishwasher . When using a dishwasher, set 
the dishwasher to a low temperature and a short 
cycle setting. The filter may become discoloured 
in a dishwasher, but this does not affect its 
performance .

 

- Dry the filters / baffle nets before re-installing them 

in the range hood .

 

- Do not allow oil to accumulate over more than 80% 

of the filter surface. Oil accumulations may drip oil 
onto the range .

Summary of Contents for QR001

Page 1: ...UNDER CABINET RANGE HOOD INSTALLATION GUIDE AND USER MANUAL Item QR015 QR060...

Page 2: ...d safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code...

Page 3: ...g Be careful to avoid burns Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Ne...

Page 4: ...rred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the respons...

Page 5: ...illips screwdriver Flathead screwdriver Needle nose pliers Hammer Electric drill or powered screwdriver Safety gloves Safety gloves Model Part Description Quantity QR015 CC Long tapping screw M5 mm x...

Page 6: ...6 Pre Installation continued PACKAGE CONTENTS C A B Model Part Description Quantity QR015 A Range Hood 1 Model Part Description Quantity QR060 B Range Hood 1 C Duct Set 1...

Page 7: ...nge hood should be approximately the same size as the cook top 2 If the bottom of the cabinet 6 above the location where the range hood is to be installed is recessed attach appropriately sized wood f...

Page 8: ...nd tape all joints with certified duct tape If you must turn the path of the duct work using elbows keep the number of elbows to a minimum for effective performance and use no more than three 90 elbow...

Page 9: ...on continued QR015 Size of the hole to be cut on the bottom of the cabinet Fig 6 10 5 8 270 mm 7 8 22 5 mm 24 3 8 620 mm Size of motor housing that needs to be inside the cabinet Fig 7 24 610mm 30 760...

Page 10: ...Size of the hole to be cut on the bottom of the cabinet Fig 8 15 380mm 10 1 4 260mm Size of motor housing that needs to be inside the cabinet 14 1 2 370mm 9 7 8 250 mm 7 1 8 182 mm 18 458mm 29 3 4 75...

Page 11: ...l connection cut a 3 2 cm 1 1 4 in hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet 8 When cutting or drilling into the wall or ceilling do...

Page 12: ...rt one end of the damper 1 into the hinge slot 2 at the top of the range hood A Gently bend the damper 1 and insert its other end into the hinge slot 2 A 1 2 1s 2 Installing the Range Hood As per Fig...

Page 13: ...If Necessary WARNING Sharp edges Wear safety gloves CAUTION Be very careful when installing the damper Applying too much force or not bending the damper enough may damage or break the damper hinge end...

Page 14: ...is recessed add a wood filler on each side The wood strips must be as thick as the recess Use appropriately sized wood screws to attach the wood filler to its location Make sure the opening hole size...

Page 15: ...g ON OFF the unit To turn on the fan press the appropriate speed control switch Low Speed 2 Medium Speed 3 High Speed 4 to select the desired level of power Once a button is pressed the previous speed...

Page 16: ...ompleted the range hood will beep the fan and lights will turn off automatically and the clock will show in the screen During the countdown operation You will still be able to change the speed by pres...

Page 17: ...Failure to replace worn out or damaged filters will increase the risk of fire WARNING Light bulbs can become extremely hot when turned on Do not touch bulbs until they are switched off and cooled Touc...

Page 18: ...allow cleaning compounds salt solutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow deposits to remain for long periods of time on the ra...

Page 19: ...system detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Check...

Page 20: ...W 12 V Type JC Top venting 12 in 305 mm D Medium 13 8 in 350 mm H Low Model Dimensions Rating Speeds CFM Control Type Illumination Venting Options QR060 29 8 in 757 mm W 120 V 60 Hz 3 6A High 700 10 P...

Page 21: ...QR001 QR003 QR006 QR009 QR014 QR015 QR019 QR060 QHR106 Control Switch 1 1 1 1 1 QHR105 Control Panel 1 1 1 QHR104 Control Panel 1 1 1 QHR100 Capacitor 5UF 370V 1 1 1 1 1 QHR102 Capacitor 10UF 370V 1 1...

Page 22: ...luminum Filter 370 mm x 320 mm 1 QHR114 Aluminum Filter 366 mm x 344 mm 2 2 QHR113 Aluminum Filter 360 mm x 200 mm 2 QHR117 Baffle Filter 366 mm x 344 mm 2 2 2 2 QHR119 Charcoal Filter 266 mm x 196 mm...

Page 23: ...Retain this manual for future use Imported by St Laurent Qu bec H4S 2C3 1 877 333 0098 www conglomkb com Made in China...

Reviews: