![Premium PFV1375MW Manual Download Page 6](http://html1.mh-extra.com/html/premium/pfv1375mw/pfv1375mw_manual_1596847006.webp)
Alarm lamps
1. Hi-Temp (High temperature alarm)
2. Door Open (Door keep open for 60 seconds alarm )
Buttons
A. Quick Freeze button
B. °C or °F temperature switch button
C. Alarm Reset button
D. Lock / Unlock button
E. Temperature setting / Quick Freeze time setting ( ) down
F. Temperature setting / Quick Freeze time setting ( ) up
Functions
Freezer temperature setting
Press buttons E (temperature down) or F (temperature up) to set the freezer temperature.
The temperature display G will blink. Set the temperature range from 7°F to -8°F, -14 °C to -22 °C).
Once the temperature is selected, press button D to set and exit. The temperature setting mode will
exit automatically after 10 seconds if no buttons are pressed
Quick Freeze Function setting
Press button A to start Quick Freeze. The temperature display will read " -11°F" or " -24°C" and
the Quick Freeze duration time is 6 hours. To stop Quick Freeze press button A again.
To change the Quick Freeze duration time, press and hold button A for 3 seconds until the time
display starts to blink to enter Quick Freeze time setting. Press buttons E or F to select the Quick
Freeze duration time of 6 hours or 48 hours. Press button D to set and exit. The time duration
setting mode will exit automatically after 10 seconds if no buttons are pressed.
For energy savings, the manufacturer recommends the 6 hours setting.