![Premium Leisure Dual Zone 18 Owner'S Manual Download Page 48](http://html1.mh-extra.com/html/premium-leisure/dual-zone-18/dual-zone-18_owners-manual_1597000048.webp)
Page 46
For HELP, call 727.573.9611
PROBLEM CAUSE
SOLUTION
Moved my
swim spa and
Wiring error at
GFCI
Check Neutral wiring of GFCI (see diagrams
on pages 10-22)
now it doesn’t
work
No power to
swim spa
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Nothing
works
Breaker has
tripped
Check and reset breaker. If problem
persists, check for loose electrical
connections. Check for Neutral wiring error
at GFCI.
Fuse blown
Check for blown fuses inside of spa pack.
Pump not
running
No power to
swim spa
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Water does
Air lock
Bleed air from the system (page 43-44)
not flow
Closed jets
Open all jets by turning counterclockwise
ACV open
Close air control valves
Water too hot
High set
temperature
Turn down set temperature on topside
control panel
High ambient
temperature
Remove the cover
Water will not
heat
Thermostat is
set too low
Check and reset to desired temperature
Air open
Close air control valve
Dirty filter
Check and clean filter
Blown fuse
Check and replace fuse
Slide valve
closed
Check and open all valves
Cover off
Put the cover back on
Swim spa in
Economy
mode
Press the Standby button and take out of
Economy
Common Error Codes:
MESSAGE MEANING
ACTION
REQUIRED
(none
)
No message on display.
Power has been cut off to
swim spa.
The control panel is disabled until
power returns. Swim spa settings
are preserved.
OHH
HH
The swim spa has shut
down from high heat
detection. One of the
sensors detected 118ºF
(48ºC) at the heater.
Do not enter the water. Remove the
cover and allow the water to cool.
Once cool, push any button. If the
swim spa does not reset, turn off
the GFCI and call service.
OHS
OH
The swim spa has
overheated and shut down.
One of the sensors
detected that the swim spa
water is 110ºF (43ºC).
Do not enter the water. Remove the
cover and allow the water to cool. At
107ºF (42ºC), the swim spa resets
automatically. If the swim spa does
not reset, turn off the GFCI and call
service.