     With the oxidizing unit installed, the unit must cycle with the furnace blower.  Wire unit to an EAC   

terminal or current-sensing relay to cycle the unit with the system fan.  If the oxidizing unit is not installed, you 

may allow unit to run continuously.  The multi-voltage ballast is self-adjusting and operates with voltages from 

120 - 240 VAC.   For 120V wiring connect the black wire to L1, white wire to neutral, green wire to ground.  

    For 240V wiring install 5 amp in-line fuses then connect the black wire to L1, white wire to L2, green wire to 

ground. Be sure power cord is secured with included strain relief connector.  Wire the unit in accordance with 

local wiring codes.  After installing, verify voltage is operating between 120 - 240 VAC with air handler operating.

Summary of Contents for MUV7-50DR

Page 1: ...1 200 pi carr s 3 Assurez vous de toujours d brancher avant l installation ou le service 4 Ne pas regarder la lampe directement avec les yeux Si n cessaire de le faire veuillez porter les lunettes de...

Page 2: ...de plenum 1 Unplug mid cord connector s by pressing the lock release marked PRESS on the connector see photo B Remove two thumb nuts holding moisture resistant lamp socket to mounting plate and remove...

Page 3: ...ver hole Secure using four self tapping sheet metal screws provided 5 Route the germicidal lamp connector s cord to the power supply 6 Disconnect blue wires from terminal 1 and 2 and reconnect blue wi...

Page 4: ...idizing unit is not installed you may allow unit to run continuously The multi voltage ballast is self adjusting and operates with voltages from 120 240 VAC For 120V wiring connect the black wire to L...

Page 5: ...e by side Clean off excess metal between the two holes with tin snips 3 Peel off the adhesive backing of the gasket on backside of mounting plate 4 Center mounting plate on hole 5 Use four self tappin...

Page 6: ...ss portion of the lamp with bare hands 4 Carefully slide the moisture lamp socket with lamp through the mounting plate into duct fitting over the mounting studs and secure using the two thumb nuts and...

Page 7: ...of two years This warranty does not cover lamps broken during shipping installation or as a result of improper handling All returns are routed through your contractor wholesaler and must be approved a...