background image

MUV7-100DR shown mounted 

on a heat pump.

1. Using the lamp mount as a template, draw the hole pattern

    on the air duct in a suitable location.

2. Using a 1 1/4 inch Vari Bit, make two holes side by side.

    Clean off excess metal between the two holes with tin snips.

3. Peel off the adhesive backing of the gasket on backside of

    mounting plate.

4. Center mounting plate on hole.

5. Use four self tapping screws provided to secure mounting 

    plate on the air duct.

UVC 

Lamp

Airflow

Power Supply Dimensions:

Size (L x W x D) 

10.625h x 5.75w x 1.75 d

Lamp Socket Dimensions:

Size (L x W x D)

3.5” x 2.75” x 1.625”

UVC 

Lamp

3099107