background image

Installation guide and Owner’s manual

 

Page 5/10

 

20201029 

Pumping stations PSA-240/H 

 

Item # 183036 

4. Installation steps 

STEP 1 – Excavating, bedding preparation and placing of the pumping station 

 

Excavate the required area by respecting the minimum distances shown 
on the adjacent illustration. 

 

Level and compact the bedding material (H2) which consists of Ø 0-20 
mm (0-¾") gravel or sand.  

 

Place the pumping station on a level and stable layer of fine gravel.  

 

The pumping station must be accessible at all times and must be 50 mm 
(2") above the surface of the landscaped lot. 

 

A maximum of two (2) PSR-140 risers is allowed.  

STEP 2 – Pipe connections 

PSA-240 and PSA-240H pumping stations: 

 

Connect the septic tank or other equipment to the pumping station using a pipe that complies with the regulations. Relier la fosse 
septique au poste de pompage avec une conduite conforme aux normes applicables. The pipe must have a minimum downward 
slope of 2% towards the pumping station. 

 

Connect the pumping station to the inlet pipe of the Ecoflo biofilter or to the required treatment system using either a flexible 38 mm 
(1½") Ø pipe for the PSA-240 or a flexible 50 mm (2") Ø pipe for the PSA-240H that can withstand at least 700 kPa (100 PSI) of 
pressure and is suitable for underground applications.  

 

In the case of an Ecoflo biofilter installation, run a rigid 100 mm (4") Ø ventilation pipe between the pumping station and the biofilter. 
A 100 mm - 38 mm (4" - 1½") Ø adaptor (Item I identified in section 2.2) is provided to complete the connection. This adaptor must 
be glued at ± 45º from the horizontal, depending on the angle at which it is easiest to install. Important: always connect the 38 mm 
(1½") Ø pipe under the 100 mm - 38 mm (4" - 1½") Ø adaptor to break the pump’s flow before the eflluent penetrates the 
biofilter. (Refer to the illustration PSA-240 pumping station before an Ecoflo biofilter in section 2.3). 

 

If the distance between the pumping station and the biofilter is greater than 20 m (70'), it is preferable to equip the biofilter with its 
own ventilation duct instead of connecting the duct to the pumping station. 

 

The pipes must be installed in a way that they drain by gravity. 

 

Precautionary measures against freezing must be taken in order to protect the pipe connecting the pumping station to the treatment 
system. 

STEP 3 – Riser installation (if required) 

When the pumping station installation requires extension risers, proceed as 
follows: 

 

Use PSR-060 (150 mm, 6") risers or PSR-140 (355 mm, 14") risers if required. 
Maximum height of risers: 710 mm (28"). 

 

Clean the access rim of the pumping station (where 4 holes were perforated to 
insert the lag screws). 

 

Install the watertight seal on the pumping station’s access rim. 

 

Align the holes of the riser with the holes of the pumping station. 

 

Insert the washers in the lag screws provided with the riser and screw them in 
place to firmly fix the riser.

 

STEP 4 – Electrical connections 

The electrical connections should be executed by an electrician. IF YOUR LOCAL ELECTRIC CODE ALLOWS IT, remove the 
connector plugs from the float and pump wires by cutting the ends and perform the electrical connections using the supplied 
waterproof screw-thread wire connectors in order to ensure the water does not affect the electrical circuit. The use of waterproof 
screw-thread wire connectors is mandatory with the electrical junction box. Note that the junction box must be installed outside of the 
pumping station, on a post above the ground surface, to prevent the box from being submerged and also to have access to the box at 
all times. 

 

PSR-060 riser 150 mm (6") or 

PSR-140 riser 355 mm (14") 

4 stainless steel 304 lag screws 

with 4 plastic washers 

Watertight seal 

Pumping station 

 

  

 

  

 

  

Summary of Contents for REWATEC PSA-240

Page 1: ...OWNER S MANUAL AND INSTALLATION GUIDE Pumping stations 2020 Made in Canada...

Page 2: ...ng station is normally used to feed low pressure distribution systems for sand filters and seepage beds when a dosing volume between 150 and 255 L is required Models PSA 240 PSA 240H Material reservoi...

Page 3: ...coupling for water outlet pipe 50 mm 2 nominal Flexible coupling for water inlet pipe 100 mm 4 nominal 2 Dimensions description and location 2 1 Dimensions PLAN VIEW PSA 240 L H pumping station base B...

Page 4: ...SA 240 and PSA 240H 2 3 Component location The PSA 240 and PSA 240H pumping stations must always be installed after the septic tank or after the effluent filter container if such is the case They shou...

Page 5: ...t damaged during transportation Ensure rapid growth of vegetation to prevent soil erosion The pumping station must be accessible at all times do not cover the lid The lid must be at least 50 mm 2 abov...

Page 6: ...lluent penetrates the biofilter Refer to the illustration PSA 240 pumping station before an Ecoflo biofilter in section 2 3 If the distance between the pumping station and the biofilter is greater tha...

Page 7: ...n The pumping station is equipped with a high water level float connected to an alarm system This alarm system must be installed inside the residence home so it can be heard when it is activated The f...

Page 8: ...astener that ties it to the reservoir do not leave the fastener in the pumping station and perform a visual inspection Then place the pump in the reservoir and connect the water outlet pipe using the...

Page 9: ...m 9 250 mm 10 na na na na 50 mm 2 200 mm 8 250 mm 10 na na na na na na The length of the cable is pre set to that length at the plant The alarm float has to be moved 50 mm higher than its initial posi...

Page 10: ...tank installer or septic tank pumper can generally take care of the situation 8 5 Odours The position of the air vent as well as other factors unrelated to the pumping station itself can prevent septi...

Page 11: ...to access to the Pumping Station including without limiting the generality of the foregoing excavation snow removal or demolition 5 PARTICULAR EXCLUSIONS It is further expressly understood that the Cu...

Reviews: