Installation guide and Owner’s manual

 

Page 4/10

 

20201029 

Pumping stations PSA-240/H 

 

Item # 183036 

3. Location, installation and operation guidelines  

It is very important to advise everyone involved (installer, landscaper, owner, snow removal service, etc.) of the 
following guidelines: 

 

 

Respect the minimum distances prescribed by regulations. 

 

Never install a pumping station in a place where the groundwater table can reach its base (otherwise, drain pipes could be required). 

 

The profile of the lot must be such that surface run off flows away from the pumping station.  

 

Never install a pumping station in clayey soil. 

 

The pumping station must be installed as close as possible to the septic tank (PSA-240/H) or to the treatment system upstream 
(PSA-240L) to minimise the depth at which it must be installed. 

 

A maximum of two (2) PSR-140 (355 mm, 14") Premier Tech risers can be installed on the PSA pumping stations. The 
maximum allowable riser height is of 710 mm (28"). IMPORTANT: take note that the PSA-240H pumping station is already 
equipped with one (1) PSR-140 riser, therefore, it is only possible to install one (1) additional PSR-140 riser. 

 

The house must be equipped with an air vent that is in proper working order and that complies with the applicable standards. 

 

For transporation purposes, it is preferable that the pumping station be in the vertical position, however, if it is not possible and the 
pumping station must be laid on its side, please proceed with precaution and make sure all the components are not damaged 
during transportation. 

 

Ensure rapid growth of vegetation to prevent soil erosion. 

 

The pumping station must be accessible at all times, do not cover the lid. The lid must be at least 50 mm (2") above the surface of 
the landscaped lot. 

 

The pumping station must be watertight and must not receive any infiltration water and should only receive the wastewater 
treatment process.  

 

Never connect a drain pipe, roof gutter, sump pump or air conditioning drain to your septic system. 

 

Never discharge water from a water softener backwash in your septic system. 

 

Never use an automatic bowl cleaner. 

 

Never overload the soil (ex: blown snow, embankment/slope) within 3 m (10') of the lid. The overload could damage the pumping 
station. 

 

Never drive vehicles or place objects weighing over 225 kg (500 lbs) within 3 m (10') of the pumping station’s lid. 

 

Never plant trees within 2 m (6'5") of the pumping station’s lid. 

 

Never open or go inside the pumping station without prior authorisation. 

 

No object must be thrown or dropped inside the pumping station. 

 

The discharge of any objects or substances into the septic tank that might clog the pumping station is proscribed. Using an effluent 
filter at the septic tank’s effluent is therefore strongly recommended in order to protect the pump and avoid any clogging or 
breakage. 

 

It is not recommended to discharge any of the following substances into the system: 

 

 

Oil and grease (motor oil, cooking oil, etc.); 

 

Wax and resins; 

 

Paints and solvents; 

 

Any kind of petroleum product; 

 

Any kind of pesticide; 

 

Any kind of septic tank additive; 

 

Any kind of toxic substance; 

 

Anything not easily biodegradable (for example, coffee beans, cigarette butts, sanitary napkins, 
tampons, condoms, cotton swab, etc.). 

 

 

 

Summary of Contents for REWATEC PSA-240

Page 1: ...OWNER S MANUAL AND INSTALLATION GUIDE Pumping stations 2020 Made in Canada...

Page 2: ...ng station is normally used to feed low pressure distribution systems for sand filters and seepage beds when a dosing volume between 150 and 255 L is required Models PSA 240 PSA 240H Material reservoi...

Page 3: ...coupling for water outlet pipe 50 mm 2 nominal Flexible coupling for water inlet pipe 100 mm 4 nominal 2 Dimensions description and location 2 1 Dimensions PLAN VIEW PSA 240 L H pumping station base B...

Page 4: ...SA 240 and PSA 240H 2 3 Component location The PSA 240 and PSA 240H pumping stations must always be installed after the septic tank or after the effluent filter container if such is the case They shou...

Page 5: ...t damaged during transportation Ensure rapid growth of vegetation to prevent soil erosion The pumping station must be accessible at all times do not cover the lid The lid must be at least 50 mm 2 abov...

Page 6: ...lluent penetrates the biofilter Refer to the illustration PSA 240 pumping station before an Ecoflo biofilter in section 2 3 If the distance between the pumping station and the biofilter is greater tha...

Page 7: ...n The pumping station is equipped with a high water level float connected to an alarm system This alarm system must be installed inside the residence home so it can be heard when it is activated The f...

Page 8: ...astener that ties it to the reservoir do not leave the fastener in the pumping station and perform a visual inspection Then place the pump in the reservoir and connect the water outlet pipe using the...

Page 9: ...m 9 250 mm 10 na na na na 50 mm 2 200 mm 8 250 mm 10 na na na na na na The length of the cable is pre set to that length at the plant The alarm float has to be moved 50 mm higher than its initial posi...

Page 10: ...tank installer or septic tank pumper can generally take care of the situation 8 5 Odours The position of the air vent as well as other factors unrelated to the pumping station itself can prevent septi...

Page 11: ...to access to the Pumping Station including without limiting the generality of the foregoing excavation snow removal or demolition 5 PARTICULAR EXCLUSIONS It is further expressly understood that the Cu...

Reviews: