Flat Panel

Griplate™

 Washer

Nylon Spacer

Mounting Bracket

Mount Point

Mounting Screw

Griplate™ Washer Installation

Premier Mounts’ Griplate™ Washers are designed to 

accommodate the various M4, M5, M6 and M8 hole 

sizes required by 

fl

 at panels.

 Do not place excessive pressure on the back of 

the 

fl

 at panel, as this may damage your 

fl

 at panel. 

The Griplate™ Washer must be installed between 

the head of the mounting screw and the mounting 

bracket as shown.

 Does your 

fl

 at panel have: 

 

Recessed mount points?

 

Uneven mount points?

 

A curved back?

 

Any obstruction near the mount point?

If 

Yes

, you must install nylon spacers.  Remove the 

mounting brackets, Griplate™ washers, and mounting 

screws from the back of the 

fl

 at panel.  Proceed to the 

“Nylon Spacer Installation”

 section.

If 

No

, skip to the 

“Flat Panel Installation”

 section.

Nylon Spacer Installation

Premier Mounts’ nylon spacers allow you to attach  the 

mounting bracket to 

fl

 at panels which have recessed 

or uneven mount points. Each nylon spacer will add 

distance between the mounting bracket and your 

fl

 at 

panel.

The nylon spacers must only be installed between 

the mounting bracket and your 

fl

 at panel.

The nylon spacers will 

fi

 t M4, M5, M6 and M8 screw 

sizes.

Proceed to the 

“Flat Panel Installation”

 section.

M8

M6

M5 

M4

Summary of Contents for ECM-3763D

Page 1: ...Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Phone 44 0 2476 614700 Fax 44 0 2476 614710 AUSTRALIA AND OCEANIA Distributed by Amber Technology Limited Unit B 5 Skyline Plac...

Page 2: ...iling Cutting or drilling into an electrical line may cause serious personal injury Make sure there are no water or natural gas lines inside the ceiling where the mount is to be located Cutting or dri...

Page 3: ...re and components Make sure that none of these parts are missing and or damaged before beginning installation If there are parts missing and or damaged please stop the installation and contact Premier...

Page 4: ...M6 x 12mm Phillips Head Screw Qty 8 M6 x 20mm Phillips Head Screw Qty 12 M6 x 30mm Phillips Head Screw Qty 12 M8 x 20mm Phillips Head Screw Qty 12 M8 x 25mm Phillips Head Screw Qty 12 M8 x 30mm Philli...

Page 5: ...Installation Instructions Page 5 Features Mounting Bracket Arm 15 Tilt Slide Decorative Cover Cable Access Port Elliptical Tilt Mount Phillips Set Screw 2 NPT Threaded Pipe not included 2 NPT Threade...

Page 6: ...ded must be firmly secured to the ceiling structure before performing the following steps Phillips Set Screw Four 4 complete revolutions 2 NPT Coupler Ensure that all connections are secure and tight...

Page 7: ...Elliptical Tilt Mount to the Dual Mounting Bracket Keyhole Slot The following steps must be completed by two people Locate the two 2 upper mounting holes located on the back of the elliptical tilt mo...

Page 8: ...rrect diameter screw for the thread insert If the screw you selected is longer than the mark on the Thread Depth Indicator as shown in Figure 2 and Figure 3 do not use this screw The screw length must...

Page 9: ...mount points A curved back Any obstruction near the mount point If Yes you must install nylon spacers Remove the mounting brackets Griplate washers and mounting screws from the back of the flat panel...

Page 10: ...ting bar of the ECM 3763D Lower and center the mounting bracket arms with the attached flat panel onto the elliptical mounting bar of the ECM 3763D Repeat steps 1 and 2 for mounting the second ellipti...

Page 11: ...e cover and mounting bracket arm Mounting Bracket Arm When attaching the decorative covers verify that the smaller mounting hole is above the larger mounting hole M4 x 6mm Screw Screwdriver M6 x 25mm...

Page 12: ...el toward you while the lower hand gently pushes the bottom of the flat panel away from you Adjusting the Flat Panel to the Original Position 1 Place one hand at the center top edge of the flat panel...

Page 13: ...OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the w...

Reviews: