background image

 

CTM-MS4

 

 

 

 

Page - 3 - 

Installation Manual  

Warning Statements

 

 

WARNING

 

PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE 
USE OF ANY PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE 
FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED 
ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY 
DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF 
WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER 
RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS. 

 

 

WARNING: 

THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING 300 LBS. IF NOT, THE 
WALL STRUCTURE MUST BE REINFORCED. PROPER INSTALLATION PROCEDURE 
BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE INSTALLATION 
INSTRUCTIONS, MUST BE ADHERED TO. FAILURE TO DO SO COULD RESULT IN 
SERIOUS PERSONAL INJURY, OR EVEN DEATH. 

 

 

WARNING: 

SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE 
INSTALLATION OF THIS PRODUCT. USE PROPER SAFETY GEAR AND TOOLS FOR 
THE INSTALLATION PROCEDURE TO PREVENT PERSONAL INJURY. 

 

 

WARNING: 

PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION 
INSTRUCTIONS SHOULD BE READ AND COMPLETELY UNDERSTOOD. THE 
INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL INJURY 
AND PROPERTY DAMAGE. KEEP THESE INSTALLATION INSTRUCTIONS IN AN 
EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE. 

 

 

Indicates that the power plug is to be 
disconnected from the power outlet. 

 

 

Contact Premier Mounts with any 
questions -  (800) 368-9700 

 

 

 

 

 

 

Safety precautions must be taken at all 
times. 

 

 

 

 

 

 

 

 

 

Warning and Caution statements. 

 

 

 

 

 

 

 

Do not install on a structure that is prone to vibration, movement or chance of impact. Failure to do 
so could result in damage to the flat panel display and/or damage to the mounting surface. 

 

 

 

Do not install near heater, fireplace, direct sunlight, air conditioning or any other source of direct heat 
energy. Failure to do so may result in damage to the flat panel display and could increase the risk of 
fire. 

 

 

 

At least two qualified people should perform the installation procedure. Injury and/or damage can 
result from dropping or mishandling the flat panel display. 

 

 

 

 

Summary of Contents for CTM-MS4

Page 1: ...9531 000 331 06 INSTALLATION MANUAL CTM MS4 Premier Mounts 3130 E Miraloma Avenue Anaheim CA 92806 Phone 800 368 9700 Fax 800 832 4888 mounts mounts com www mounts com...

Page 2: ...f Contents Warning Statements 3 Parts List 4 Installation Tools 4 Mounting Bracket Installation 8 CTM MS4 Installation 11 Installing the Flat Panel Display CTM MS4 14 Technical Specifications 17 Warra...

Page 3: ...THE INSTALLATION PROCEDURE TO PREVENT PERSONAL INJURY WARNING PRIOR TO THE INSTALLATION OF THIS PRODUCT THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND COMPLETELY UNDERSTOOD THE INSTALLATION INSTRUC...

Page 4: ...n and contact Premier Mounts 800 368 9700 Wall Plate Qty 2 Mounting Brackets Qty 2 5 16 Flat Washers Qty 12 5 16 x 3 Lag Bolts wooden studs only Qty 12 M6 x 30mm Lateral Shift Locking Screws Qty 2 Gri...

Page 5: ...25 Qty 8 M8 x 30 Qty 8 M6 x 30 Qty 8 M8 x 35 Qty 8 M8 x 70 Qty 4 Nylon spacers and flat washers actual size NOTE The nylon spacers may be stacked to achieve proper spacing Nylon Spacers Qty 8 Nylon Sp...

Page 6: ...correctly install the mounting plate 3 Anytime a display has a recessed mounting point a spacer must be used 4 Select the spacer s that will create a flush and level mounting surface for the mounting...

Page 7: ...rking to the screws supplied 3 If your selected screw is longer than the marking on the thread depth indicator DO NOT USE this screw 4 The screw length must not bypass the marking Select another screw...

Page 8: ...NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO THE GLASS THE FLAT PANEL IS HEAVY AND FRAGILE AT LEAST TWO QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT F...

Page 9: ...s stamped arrows facing out Figure 7 Figure 6 Figure 7 5 Match the center of viewing guide with the centerline you marked in Step 1 Figure 8 6 The mounting brackets are designed with a center of viewi...

Page 10: ...g brackets are aligned secure the Griplate to the flat panel Use 1 Griplate per mounting point Figure 11 NOTE The dimples of the top Griplate have to be facing up and the bottom Griplate dimples must...

Page 11: ...wall plate to the reference line and mark the lag bolt mounting points through the wall plate slots on the wall see NOTE below 16 16 Figure 12 Figure 13 NOTE Three studs that are 24 apart will need n...

Page 12: ...t the hex head bolts through the two holes and secure with M8 Hex nuts Figure 14 6 Thread the provided set screw into one end of the support rod and mount Once the lower rod is mounted thread in the r...

Page 13: ...ence arrow pointing up to the ceiling Figure 15 7 Drill pilot holes to the marked wall 8 Secure the plate using the 5 16 lag bolts and flat washers Figure 16 16 Figure 15 Figure 16 Wood Installation W...

Page 14: ...OMMENDED FOR INSTALLATION OF THIS PRODUCT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL 1 Raise the flat panel with the mounting brackets secured to the flat pa...

Page 15: ...ening the screws found on the bottom of the mounting brackets CAUTION Do not over tighten the screws to the rods Figure 18 NOTE To remove the display from the wall simply loosen the screws using a Phi...

Page 16: ...to each of the mounting brackets Figure 19 NOTE To remove the display from the wall simply extend the display to its maximum tilt range remove the safety knobs push the flat panel back to it s flat p...

Page 17: ...CTM MS4 Installation Manual Page 17 Technical Specifications Figure 20...

Page 18: ...NESS FOR A PARTICULAR PURPOSE Contact Premier Mounts In the event of missing and or damage equipment or technical questions the following information can help in the completion of the installation Cus...

Reviews: