Installation Guide
TVF -
www.premiermounts.com | North America 800.368.9700 | Interna1-714-632-7100
1
Page 7
00.0
o
LASER / LEVEL
Wall Anchor Plate
Wall Anchor Plate
WALL
WALL
1. Install (2) 5/8”-11 Bolt with Hole onto the threaded extrusion.
2.
Place the first Horizontal Rail on the wall.
3.
Secure the first mounting location by sliding a Wall Anchor Plate behind the mount and fasten
using 5/16” x 3 Hex Lag and 5/16” Washer.
4. Maintain a 1/8” minimum gap from the anchor plate and the rail when anchoring.
5. Level, Square, Plumb.
6. Install the remaining lag bolts, washers, and wall anchor plate.
METHOD 2
1/8” min.
gap
Clearance
5/16” x 3”
Hex Lag
5/16 Washer
5/8”-11 Bolt
With Hole
Wall Anchor
Plate
Horizontal
Rail