Prepare cable for expressed fiber  
(buffer tube window cut) applications.

For Applications Where Fiber is  

Expressed through the Buffer Tube

Sheath Opening

96" (2.4 m)

Buffer Tube  

Opening Location

C (see image 

above)

Buffer Tube 

Opening 

Locations for 

Window Cut

C

X

X

C

96" (2.4 m)

OFFICE/C

.O.

Step #9 If shielded cable is being used, install 

shield connector on shielded cables.  
See Step #16 for recommended  
bonding practice.

Follow standard company practices.

Step #10a Lubricate the outer surface of the 

grommet. 

Lubricate seal-

ing surface of 

grommet with 

silicone lubri-

cant provided.

Step #10b Position grommet in end plate slot.

For Wide Range 2-Hole 

Grommets, make sure 

arrows are pointing down 

when inserting grommet(s).

Do not align grommet slit 

with end plate seam.

Step #12

Step #11

Install cable cap and secure with hex 
bolts. Tighten bolts by hand evenly  
until cable cap is fully seated. 

(DO 

NOT USE POWER TOOLS TO  
TIGHTEN BOLTS).

Important Note: 
Tighten all unused cable caps.

Complete end plate assembly.

PLP Tip: 

To start cable cap bolts, apply 
pressure with thumb and line 
up bolts with inserts. Engage 
1 or 2 threads on one of the 
bolts. Repeat the process on 
opposite bolt. Alternate tight-
ening until fully seated.

Step #8c

Summary of Contents for 800012184

Page 1: ...escription 800012185 COYOTE Dome Cross Connect Closure 6 5 x 17 Includes 2 Grommets 1 Cross Connect Organizer Assembly with 4 Port End Plate Assembly 1 Dome 1 Collar Assembly 1 Gasket 8 Plastic Organi...

Page 2: ...r Coded SC SM 3 meter P12FC3 12 Simplex 900 Micron Color Coded FC SM 3 meter P6SCA3 6 Simplex 900 Micron Color Coded SC SM APC 3 meter P12FC5 12 Simplex 900 Micron Color Coded FC SM 5 meter P12SCA3 12...

Page 3: ...met 8003694 1 0 1 25 25 32 mm 1 entry grommet 8003663 42 60 11 15 mm 2 entry grommet 8003990 50 60 12 7 15 2 125 25 3 2 6 4 and flat drop 4 entry grommet 8003664 30 43 8 11 mm 4 entry grommet 8004065...

Page 4: ...ase Position sup port bracket onto base and secure with wing nuts Note Do not tighten wing nut until end plate is installed Base can be secured to work surface with either clamps or with bolts Loosen...

Page 5: ...on Step 7 Grommet Slitting If slitting is required lay grommet on a stable flat surface Position utility knife with the cutting edge against the top surface and cut through grommet Consult grommet cha...

Page 6: ...icate seal ing surface of grommet with silicone lubri cant provided Step 10b Position grommet in end plate slot For Wide Range 2 Hole Grommets make sure arrows are pointing down when inserting grommet...

Page 7: ...th hose clamp PLP Tip Avoid contact between hose clamp and shield connector to maintain isolation of each cable ground Organizer Preparation Step 16 Attach bonding device between the cable and ground...

Page 8: ...cm Step 21a Step 20 Select feeder fiber to be spliced Route and store buffer tubes in storage brackets X Cut fiber to be spliced here Cut fiber Secure adapter plate assembly to mainframe with fastener...

Page 9: ...te and press into groove Make sure gasket is seated in groove of end plate Step 30 Re tighten all cable cap bolts step 11 to assure that the cable caps are fully seated When using a can wrench or nut...

Page 10: ...e collar in place push against the end of the dome and slightly lift and push the other half of the dome up and over the lip of the collar with your fingers to fully install the dome in the collar hal...

Page 11: ...end plate Step 40 Pressurize closure up to a max of 10 psi Step 42 Release the pressure in the closure using the bump on the top of the air valve cap Step 41 Spray all sealing surfaces of the dome en...

Page 12: ...the corner of the cable port Leak occurring at the cable entry of the grommet due to the cable not being within the stated cable diameter range of the grommet To resolve remove collar and remove End P...

Page 13: ...cket with the bolts and keps nuts provided For 6 5 Dome Strand Mount Aerial Offset Bracket Kit P N 8004035 and 6 5 Dome ADSS Mount Aerial Offset Bracket Kit P N 8004036 Step 43c Position 1 Strand Clam...

Page 14: ...and hole using 2 screws Step 48 COYOTE Universal Mounting Bracket for Hand Hole Applications P N 8003835 Insert banding plastic or metal through the slots of the hanger brackets COYOTE Universal Mount...

Page 15: ...lates are secure Stud Mount Plate 1 8 3mm Stud Mount Plate Pole Wall Mount Bracket Secure Lock Nuts The 6 5 COYOTE Dome Pole Wall Mount Bracket P N 8003702 Step 54 Attach the COYOTE Dome closure to th...

Page 16: ...red trademark of the DuPont Company Step 55b The COYOTE Dome Mount Aerial Bracket Kit for ADSS Cat No 8003833 can be used to suspend the COYOTE 6 5 x 17 or 6 5 x 22 Dome Closure from ADSS cable To ins...

Reviews: