8
User Manual
All illustrations in this manual are for information purposes only and may differ from the product supplied by us.
Remark:
Disinfection and charging can go hand in hand. Put away your devices and close the doors and follow the steps below.
UV Operation:
Briefly press the UV (on/or) button to switch on the disinfection programme. This will only start once the door is closed. The
disinfection will take 30 minutes as standard, after which the UV-C lamps will automatically turn off again. In the unlikely
event that the cabinet door is opened during disinfection, the UV-C lamps are automatically turned off.
Set disinfection time:
The disinfection time is set to 30 minutes as standard and, in practice, this is more than sufficient.
However, if you would prefer this programme to be shorter or longer, you can set this yourself.
Press and hold in the UV button for more than 3 seconds to open the timer menu. The button lamp will flash. The number
of times the LED flashes represents the disinfection time. A short press of the UV button changes the flashing light.
•
1x flashing is 15 minutes
•
2x flashing is 30 minutes
•
3x flashing is 45 minutes
When the desired disinfection time has been selected, press and hold in the UV button again for at least 3 seconds. The
button will stop flashing.
Setting the UV Switch and disinfection time