background image

Page 8

For technical questions, please call 1-888-866-5797.

ITEM 69674 

        

Sa

Fety

Setup

Opera

ti

O

n

Maintenance

initial tool Set up/assembly

  read the entire iMpOrtant SaFety inFOrMatiOn section at the beginning of this 

manual including all text under subheadings therein before set up or use of this product.

tO preVent SeriOuS inJury: 

Operate only with proper spark arrestor installed.

Operation of this equipment may create sparks that can start fires around dry vegetation. 

a spark arrestor may be required. the operator should contact local fire agencies 

for laws or regulations relating to fire prevention requirements.

Grounding

The Generator must be properly grounded before use. Have the unit grounded 

by a qualified electrician if you are not qualified to do so.

To ground the Generator, connect a #6 AWG grounding wire (not included) from the 

Grounding Terminal on the Control Panel to a grounding rod (not included) that has been 

driven at least 24 inches deep into the earth. The grounding rod must be an earth‑driven 

copper or brass rod (electrode) which can adequately ground the Generator.

nOtice:

 This generator is not intended to power sensitive electronic equipment without the addition of an 

appropriate line conditioner and surge protector (both not included).  

Sensitive electronic equipment includes, 

but is not limited to, audio/video equipment, some television sets, computers, and printers. 

Sensitive 

electronic equipment should be operated on approved inverter type generators or pure sine wave generators.

note:

 For additional information regarding the parts listed in the following pages, 

refer to the Assembly Diagram near the end of this manual.

note:

 Wheel Kit, item # 68531 (sold separately) can be used with this generator.

Operating instructions

  read the entire iMpOrtant SaFety inFOrMatiOn section at the beginning of this 

manual including all text under subheadings therein before set up or use of this product.

inspect tool before use, looking for damaged, loose, and missing parts.  

if any problems are found, do not use tool until repaired.

Generator pre-Start checks

Inspect engine and equipment, looking for damaged, loose, and missing parts before set up 

and starting.  If any problems are found, do not use equipment until fixed properly.

checking and Filling engine Oil

cautiOn!

  

your Warranty is VOiD if the engine’s crankcase is not properly filled with oil before 

each use.  Before each use, check the oil level.  Do not run the engine with low or no engine oil.  

running the engine with no or low engine oil WiLL permanently damage the engine.

1.  Make sure the engine is stopped and is level.

2.  Close the Fuel Valve.

3.  Clean the top of the Dipstick and the area around it.  Remove the Dipstick by 

threading it counterclockwise, and wipe it off with a clean lint free rag.

Summary of Contents for 69674

Page 1: ...the product is intact and undamaged If any generator parts are missing or broken please call 1 888 866 5797 as soon as possible Visit our website at http www harborfreight com email our technical sup...

Page 2: ...ecautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 2 Have multiple ABC cl...

Page 3: ...l spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spilled Clean spilled gasoline before sta...

Page 4: ...from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sense when operating thi...

Page 5: ...gles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight...

Page 6: ...gasoline Capacity 6 1 Gallons 23L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit...

Page 7: ...r 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator from o...

Page 8: ...c equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or p...

Page 9: ...he Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before...

Page 10: ...etor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back agai...

Page 11: ...controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small a...

Page 12: ...s and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate...

Page 13: ...o stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before t...

Page 14: ...uipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems imme...

Page 15: ...changing oil 1 Make sure the engine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt t...

Page 16: ...o remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water will gradu...

Page 17: ...spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connect...

Page 18: ...ipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilize...

Page 19: ...NTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUT...

Page 20: ...pring Throttle Return 1 81 Rod Governor 1 82 Arm Governor 1 83 Bolt Governor Arm 1 84 Nut Flange M6 1 85 Cover Dust 1 86 Bolt Flange M5 10 3 87 Grommet Crankcase 1 88 Bolt Flange 4 89 Stay Comp Muffle...

Page 21: ...Page 21 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram...