![Precor Bicycle-mounted Child Seat C842 Service Manual Download Page 23](http://html1.mh-extra.com/html/precor/bicycle-mounted-child-seat-c842/bicycle-mounted-child-seat-c842_service-manual_1594660023.webp)
C842, C842i, C846, C846i Upright and Recumbent Cycle
Page 23
Procedure 6.1 - Troubleshooting the Interconnect Cables
7. For C842, C842i, C846i and C846 version 2 units, skip to step 18. For C846 version 1 units,
continue with step 2.
8. Set the on/off switch in the “off” position.
9. Both the upper and lower interconnect cable are easily disconnected at both ends.
Therefore, the simplest way to troubleshoot the interconnect cables is to by-pass them with
a known good interconnect cable.
10. Remove the left hand cover per Procedure 7.1.
Troubleshooting the upper interconnect cable
11. Remove the display housing per Procedure 7.13. Disconnect the upper interconnect cable
from the upper PCA.
12. Disconnect the upper interconnect cable from the junction block at the base of the upright
column.
Diagram 6.1 - Interconnect Cables, C846 version 1
13. Connect the by-pass interconnect cable to the upper PCA and the junction block.
J
unction Block
Lower
Interconnect Cable
Upper Interconnect Cable