3. Contraindications

Should be used with caution on infants, pregnant women, hemophiliacs and

patients with heart problems.

4. Adverse Reactions

● Patients may feel tense, uncomfortable or experience pain during use of the device.

● Patients hearing may be affected during use of the device.

1. Indication for Use

● This air motors is intended to operate/drive dental handpiece attachments

for dental applications.

● To be used for dental treatments by trained dental professionals.

2. Precautions for Handling and Operation

● Devices are only to be used for the purpose specified in Intended for Use.

● All precautions should be read and understood before use.

● Instructions are provided in order to prevent the risk of personal injury or damage

to the dental handpiece.

WARNING: 

Indicates a hazard that may result in serious injury/device 

damage if instructions are not correctly followed.

CAUTION: 

Indicates a hazard that may result in mild to moderate 

injury / device damage if instructions are not correctly followed.

CAUTION

● Users are required to protect themselves, the patient and third parties from danger.

● Users are responsible for correct and intended usage, regular maintenance and

continual inspection of the air motor.

● Avoid impact or contamination of air motor.

● Do not disassemble or alter the air motor except as recommended in our user

instructions.

● Correct eye, face and personal protection must be used by operator, assisting

staff and patient whilst air motor is being used.

● If the air motor begins operating abnormally, immediately stop use and contact

your authorized Precision Plus dealer.

● Air motor is supplied in a non-sterile state and must be autoclaved before use.

● Air motor should be carefully tested for vibration, noise or overheating prior to use,

if it has not been used for a long time.

USER MANUAL

DENTAL AIR MOTOR

For your safety and the safety of your patients please read this user manual 

carefully before use and file for future reference.

This manual is published by Precision Plus.

Precision Plus does not guarantee its contents and reserves the right to amend

without prior notice. Amendments will be published in new editions of this manual.

L30 Air Motor

L30 Rev. V2.

3

 © Precision Plus

L30-M4

Summary of Contents for L30

Page 1: ...lowed CAUTION Users are required to protect themselves the patient and third parties from danger Users are responsible for correct and intended usage regular maintenance and continual inspection of the air motor Avoid impact or contamination of air motor Do not disassemble or alter the air motor except as recommended in our user instructions Correct eye face and personal protection must be used by...

Page 2: ...art or contact your authorized Precision Plus dealers if problem persists Model L30 M4 4 holes Hose Connection Type ISO 9168 Type 2 Midwest 4 holes Handpiece Connection Type ISO 3964 Air Supply Pressure 3 kg cm 42 p s i Negative Rotating Speed of Motor 3 kg cm Positive Rotating Speed of Motor 3 kg cm Maximum Speed 20 000 r p m 10 20 000 r p m 10 20 000 r p m 10 Air Consumption 3 kg cm 66NL min Rat...

Page 3: ...ds Clean the surfaces with a soft bristle brush 10 2 2 Pre cleaning Use a washer disinfector meeting the requirements of the ISO 15883 series Put the instrument into the machine on a tray Connect the instrument with the WD by using suitable adapter and start the program 4 min pre washing with cold water 40 C emptying 5 min washing with a mild alkaline cleaner at 55 C emptying 3 min neutralising wi...

Page 4: ...ng blood on outer surface may become clotted and cause operational failure Do not use autoclaves exceeding 137 C during sterilization Sterilize according to EN13060 class B Always follow autoclave manufacturer s instructions for use Reprocessed products should be stored protected from dust in a dry dark and cool place with minimum exposure to germs Autoclave sterilization is the only agreed method...

Page 5: ...sion Plus parts installed Replacement parts will be made available for seven years after the date of discontinuation of the model In order to avoid the health risks to operators handling the disposal of medical devices as well as the risks of environment contamination caused thereof a surgeon or a dentist is required to confirm the device is sterilized prior to disposal Ask a specialized firm who ...

Reviews: