© 2020 Precision Lighting Ltd.    We reserve the right to change details of design, materials and finish.    Version   11.20

33

These instructions are applicable to all 
luminaires including:
Solo 11 - Surface
Solo 16 - Surface
Solo 16 Plus - Surface

WARNING 
Do not exceed maximum number of 
luminaires per driver wattage rating, see 
driver datasheet for details.
Remote access required for driver.

   

WARNING 

mains supply to driver must 

be OFF before connecting or disconnecting 
fittings. Do not connect or disconnect 
under load.  
Ensure driver has not been powered for a 
minimum of 1 minute before reconnecting 
the LED module after disconnecting. 
Do not hot plug. Failure to follow this 

   

WARNING 

1-2 luminaires per DRIVER

   

WARNING 

1-2 luminaires per DRIVER

instruction will lead to serious damage 
of the LED module and driver and will 
not be covered by warranty.      

   

 NOTE

 

Wire specification: 22 AWG, 

ø0.65mm diameter double insulated 

teflon wire.  

Red - Positive 

Black - Negativ

1. Connect Solo luminaires in series to 

the driver LED outlet. 

Maintain correct polarity when wiring. 

Incorrect wiring will cause serious 

damage and will not be covered by 

warranty. Must be installed according to 

SELV regulations.          

2. Wire 1-10V or DALI control to LED 
driver.              

Maintain correct polarity when wiring 

dimming control wire. Incorrect wiring 

will cause serious damage and will 

not be covered by warranty. Must be 

installed according to SELV regulations.

1.  All systems must be installed by a suitably 

qualified  professional  only.  Installations 
must conform to national installation 
and accident prevention regulations.

2.  Ensure that the luminaire is switched off at 

mains supply before installing or removing.

3.  Do not install these systems in a damp 

or  wet  location,  IP20  environments 
only.  Do  not  install  any  fixture  closer 
than  150mm  (6  inches)  from  any 

combustible material. 

4.  To reduce the risk of fire and burns, do 

not install these systems where exposed 
bare conductors can be shorted or 
contact any conductive materials. Do not 
conceal or extend exposed conductors 
through a building wall.

5.  Ensure  all  connections  are  tight.  Bad 

connections  can  cause  overheating, 
arcing and a potential fire risk. 

6.  Wire supply connections must be made 

with U.L or compatible testing agency-
approved  connectors.

 

Always  use 

appropriate optics and ensure they are 
fitted securely.

7.  Install and use only as described in this 

Precision Lighting manual. 

8.  Use  Precision  Lighting  recommended 

optics and accessories only. 

9.  Luminaires  may  be  hot,  allow  to  cool 

before touching.

10.  Access  to  serviceable  electrical 

components  should  be  kept  available 
for maintenance purposes. 

11.  Regular  cleaning  of  these  products  is 

important.  Switch  off  at  mains  supply 
and  allow  to  cool  before  touching. 
Clean  fittings  with  a  microfibre  cloth. 
Then reconnect the power supply.

instruction manual

Solo 11 / 16 / 16 Plus Surface 

Electrical Installation

350mA (11 series) or 700mA 

(16 series) Constant Current 

Driver.

1 -10V
/ DALI

1 -10V
/ DALI

MAINS

MAINS

350mA Constant
Current Driver

Output / 

Secondary

Output / 

Secondary

Solo 11 Surface

Solo 16 & 16 Plus 

Surface

700mA Constant
Current Driver