PD6830 Pulse Input Rate/Totalizer Instruction
Manual
39
Disabling Password Protection
To disable the password protection, access the Password menu and enter the correct
password twice, as shown below. The meter is now unprotected until a new
password is entered.
Enter
Password
3024.7
GALLONS
Run Mode
LOCKED
0
0000
LOCKED
SETUP
0
0000
PASSWRD
PASSWRD
UNLOCKD
Re-Enter
Password
UNLOCKD
Run Mode
If the correct six-digit password is entered, the meter displays the message
UNLOCKD
(unlocked) and the protection is disabled until a new password is programmed.
If the password entered is incorrect, the meter displays the message
LOCKED
for
about two seconds, and then it returns to Run Mode. To try again, press Enter while
the Locked message is displayed.
Did you forget the password?
The password may be disabled by entering a master
password. If you are authorized to make changes, enter
the master password 50865 to unlock the meter
permanently. Unlike password disabling, the master
password is entered only once to unprotect the meter.
Summary of Contents for ProtEX-RTP PD6830
Page 55: ...PD6830 Pulse Input Rate Totalizer Instruction Manual 55...
Page 57: ...PD6830 Pulse Input Rate Totalizer Instruction Manual 57 NOTES...
Page 58: ...PD6830 Pulse Input Rate Totalizer Instruction Manual 58 NOTES...
Page 59: ...PD6830 Pulse Input Rate Totalizer Instruction Manual 59 NOTES...