Maximum and Minimum Readings
The main function of the front panel buttons during operation is to dis-
play the maximum and minimum readings.
237.3
Hi
lo
246.8
229.1
Press
to Hold Max/Min
Enter
Press
to Display and to
Toggle Between Max & Min
Up
Press
to Reset Max/Min
Right
Press
to Exit Max/Min
Menu
10 Sec Timeout
Actual
Reading
1. Press
Up
arrow/
Max
button to display maximum reading since the
last reset/power-up.
2. Press
Up
arrow/
Max
again to display the minimum reading since
the last reset/power-up.
3. Press
Enter/Ack
to hold Max/Min display reading, the meter will
continue to track new Max/Min readings.
4. If
Enter/Ack
is not pressed, the Max/Min display reading will time
out after ten seconds and the meter will return to displaying the ac-
tual reading.
5. Press
Right
arrow/
Reset
button to reset Max/Min while reading is
being displayed. Max/Min display readings are reset to actual
reading.