3
PD6210 / PD6310
P
ro
V
U
®
Batch c ontrollers
easy to Use
The user friendly dual-line display makes the P
RO
V
U
easy to set
up & program. No jumpers to set for input selection. All setup &
programming are done via the front panel.
Batch c ontroller
c a Pa BIl It Ies
A P
RO
V
U
batch controller can be programmed for a wide variety
of applications. Setup is easy for single or multi-stage batching.
Automatic overrun correction keeps the batch size accurate, even
over time and with system wear. It can record grand total, or non-
resettable grand total with a time base of seconds, minutes, hours
or days. The user can program a conversion factor, and configure a
non-resettable grand total, and password protection.
single and multi-stage Batching
The P
RO
V
U
can be used as a single or multi-stage batch controller.
Relays assigned to the total act as batch control relays, with
additional relays beyond the first including a preclose value. The
preclose deactivates the relay before the batch is finished, to allow
slower fill rates and a more accurate batch finish. With expansion
module relays, up to eight-stage batching is possible. Each
additional stage batching relay has an individually programmable
preclose amount.
manual or a utomatic Batch c ontrol
Batches may be started manually with the START front panel
button, or with a remote digital input trigger. Batches may also be
programmed to start automatically after a 0 to 999.9 second delay
after the end of the last completed batch. A manually stopped batch
will not automatically restart. The START button or digital input
must be used.
a utomatic o verrun c orrection
The P
RO
V
U
batch controller will correct for batch overrun or
shortages automatically. By tracking the amount the batch was off
by, the controller will automatically adjust the batch by modifying
the batch relay deactivation time.
Quick Preset c hanges
The front panel BATCH key is configured by default to access
the preset menu. The preset may be changed quickly and easily
between batches without the need to enter setup menus.
non-r esettable Grand t otal
The user can set up the grand total to be non-resettable by entering
a specific password. Once this is done, the grand total can never
be reset.
t otal c onversion Factor
The user can enter a conversion factor that allows the controller
to display total in different units than the rate. For instance, an
operator could measure flow rate in gallons per minute and grand
total in hundredths of acre-feet.
Grand t otal & r ate a larms
The P
RO
V
U
’s four internal and four external relays can be set up
to alarm when the grand total reaches a user-defined set point or
when the rate is above or below a certain value. Rate alarms are
only activated when the batching process is running. A variety of
reset modes are available and the user can also program time
delays and fail-safe operation.
o n-Board Digital Input
The PD6210 and PD6310 include a digital input as standard. This
digital input can operate with the tare, reset tare, or interlock relays
feature, force relays on from a signal from a PLC or relay on other
equipment, and much more. This is ideal for installations where the
meter is inaccessible behind a cover, or where an additional function
key is needed for customized operation.
P-
COM
P+
V+ mA+
3
4
1
2
5
F4
6
Input setup
Display setup
c learly l abeled Displays
The upper display alternates the display to show the controller state
when in pause or stop mode. When displaying rate, grand total,
batch count, or preset, the lower display alternates between the
display value and the function or unit of measure.
Grand t otal Displays Up to 9 Digits
These batch controllers can display up to nine digits of total flow
with the grand total feature. In the diagrams below, the batch
controller is displaying 532,831,470 by toggling between a display
of “oF 532” and “831470”. Notice the (GT with arrow
▲
symbol) is lit
up indicating the display is in a grand total overflow mode.
a lternating Display
Batch t otal & Preset