PD6210 / PD6310 

P

ro

V

U

®

 

Batch c ontrollers

easy to Use

The user friendly dual-line display makes the P

RO

V

U

 easy to set 

up & program. No jumpers to set for input selection. All setup & 
programming are done via the front panel.

Batch  c ontroller 

c a Pa BIl It Ies

A  P

RO

V

U

 batch controller can be programmed for a wide variety 

of applications. Setup is easy for single or multi-stage batching. 
Automatic overrun correction keeps the batch size accurate, even 
over time and with system wear. It can record grand total, or non-
resettable grand total with a time base of seconds, minutes, hours 
or days. The user can program a conversion factor, and configure a 
non-resettable grand total, and password protection.

single and multi-stage Batching

The P

RO

V

U

 can be used as a single or multi-stage batch controller. 

Relays assigned to the total act as batch control relays, with 
additional relays beyond the first including a preclose value. The 
preclose deactivates the relay before the batch is finished, to allow 
slower fill rates and a more accurate batch finish. With expansion 
module relays, up to eight-stage batching is possible. Each 
additional stage batching relay has an individually programmable 
preclose amount.

manual or a utomatic Batch c ontrol

Batches may be started manually with the START front panel 
button, or with a remote digital input trigger. Batches may also be 
programmed to start automatically after a 0 to 999.9 second delay 
after the end of the last completed batch. A manually stopped batch 
will not automatically restart. The START button or digital input 
must be used.

a utomatic o verrun c orrection

The P

RO

V

U

 batch controller will correct for batch overrun or 

shortages automatically. By tracking the amount the batch was off 
by, the controller will automatically adjust the batch by modifying 
the batch relay deactivation time. 

Quick Preset c hanges

The front panel BATCH key is configured by default to access 
the preset menu. The preset may be changed quickly and easily 
between batches without the need to enter setup menus.

non-r esettable Grand t otal

The user can set up the grand total to be non-resettable by entering 
a specific password. Once this is done, the grand total can never 
be reset.

t otal c onversion Factor

The user can enter a conversion factor that allows the controller 
to display total in different units than the rate. For instance, an 
operator could measure flow rate in gallons per minute and grand 
total in hundredths of acre-feet. 

Grand t otal & r ate a larms

The P

RO

V

U

’s four internal and four external relays can be set up 

to alarm when the grand total reaches a user-defined set point or 
when the rate is above or below a certain value. Rate alarms are 
only activated when the batching process is running. A variety of 
reset modes are available and the user can also program time 
delays and fail-safe operation.

o n-Board Digital Input

The PD6210 and PD6310 include a digital input as standard. This 
digital input can operate with the tare, reset tare, or interlock relays 
feature, force relays on from a signal from a PLC or relay on other 
equipment, and much more. This is ideal for installations where the 
meter is inaccessible behind a cover, or where an additional function 
key is needed for customized operation.

P-

COM

P+

V+ mA+

3

4

1

2

5

F4

6

Input setup

Display setup

c learly l abeled Displays

The upper display alternates the display to show the controller state 
when in pause or stop mode. When displaying rate, grand total, 
batch count, or preset, the lower display alternates between the 
display value and the function or unit of measure.

Grand t otal Displays Up to 9 Digits

These batch controllers can display up to nine digits of total flow 
with the grand total feature. In the diagrams below, the batch 
controller is displaying 532,831,470 by toggling between a display 
of “oF 532” and “831470”. Notice the (GT with arrow 

▲ 

symbol) is lit 

up indicating the display is in a grand total overflow mode.

a lternating Display

Batch t otal & Preset

Summary of Contents for PRO VU Series

Page 1: ...ture C ount Up or Down with Each Batch C ommon PRO VU METER Fea t ures NEMA 4X IP65 Front Input Power O ptions Include 85 265 VAC or 12 24 VDC Dual L ine 6 Digit Display 0 60 0 46 Programmable Displays Function Keys O ptional SunBright Display Models for O utdoor A pplications 2 or 4 R elays Isolated 4 20 mA Output Options External 4 R elay Digital I O Expansion Modules RS 232 RS 485 Serial C ommu...

Page 2: ...may be displayed in the lower display with password protection and non resettable programmable features Dual Line 6 Character Display Large 0 6 Digits Rugged Front Batch Preset Current Batch Quantity Start Batch Preset Stop Keys Batch Control Alarm Relays Total Super Bright LEDs make Standard and SunBright Display Models Even Brighter The PROVU s standard and SunBright display models feature extra...

Page 3: ...CH key is configured by default to access the preset menu The preset may be changed quickly and easily between batches without the need to enter setup menus Non R esettable Grand T otal The user can set up the grand total to be non resettable by entering a specific password Once this is done the grand total can never be reset T otal C onversion Factor The user can enter a conversion factor that al...

Page 4: ...keys on the front panel without a password Level 2 protection allows the operator use of only the function keys and the ability to change set points without a password Level 3 protection restricts the function keys and all configuration menus without a password Grand total reset protection prevents the total from being reset manually R ugged A unique front panel design makes the PROVU nearly impen...

Page 5: ...batch total equals the preset amount the restricted flow valve closes The barrel is now full If some overrun occurs the next batch will adjust for this offset amount to maintain accuracy C hange Preset After placing a new empty barrel a new preset fill amount may be selected with the Batch key while the process is stopped Begin New Batch Press the START key and a new batch will begin With both val...

Page 6: ...ls rated 200 mA max 12 24 VDC powered models rated 100 mA max 50 mA max for 5 or 10 VDC supply Normal R ejection Mode Greater than 60 dB at 50 60 Hz PD6210 Isolation 4 kV input output to power line 500 V input to output or output to P supply O vervoltage C ategory Installation Overvoltage Category II Local level with smaller transient overvoltages than Installation Overvoltage Category III Environ...

Page 7: ... illuminated while displaying batch total and GT for grand total Up to 999 999 999 with total overflow feature oF is displayed to the left of grand total overflow and LED is illuminated Batch T otal Decimal Point Up to five decimal places or none d ddddd dd dddd ddd ddd dddd dd ddddd d or dddddd Total decimal point is independent of rate decimal point T otalizer Calculates total based on rate and ...

Page 8: ...loads or der ing informa t ion PRO VU PD6210 A nalog Input 85 265 VAC Model 12 24 VDC Model O ptions Installed PD6210 6R2 PD6210 7R2 2 Relays PD6210 6R4 PD6210 7R4 4 Relays PD6210 6R5 PD6210 7R5 2 Relays 4 20 mA Output PD6210 6R7 PD6210 7R7 4 Relays 4 20 mA Output To order SunBright display models replace the R with H i e PD6210 6H2 Note 24 V flowmeter power supply standard on all models PRO VU PD...