Precision Digital Corporation PRO VU Series Manual Download Page 2

www.CABriggs.com

2

PD6210 / PD6310 

P

ro

V

U

®

 

Batch c ontrollers

UV Resistant

Sunlight Readable Models

Front Panel 

NEMA 4X Rated

Int UIt IVe Ba tch  c ontrol

The front panel has intuitive buttons and displays that make 
operating the batch controller clear and easy right out of the 
box. START, BATCH, and STOP buttons come setup by default 
for batch controller operation. The START button is used to 
begin a batching process. The BATCH button is used to quickly 
access the preset value. The STOP button can be pressed 
once to pause a batch, or twice to cancel a batch in progress. 
The upper and lower displays can be easily configured for your 
application need. The STOP button may be used to easily 
cycle the lower display information while the batch is stopped. 
 

easily c hoose Your Display Information

Batch t otal & Preset

The preset on the lower display 
provides even quicker access 
to the preset menu just by using 
the arrow keys to change the 
value.

Batch t otal & r ate

The rate on the lower display 
may be alternated with units for 
variable flow batching systems. 
Rate alarms may also be used 
during the batch process.

Batch t otal & Batch c ount

The batch count on the lower 
display, tracks completed 
batches. The count may be set 
back to 0 with the reset menu.

Batch t otal & Grand t otal

A grand total with overflow digits 
for up to a 9 digit total may be 
displayed in the lower display, 
with password protection and 
non-resettable programmable 
features.

Dual-Line

6-Character

Display

Large 

0.6" Digits

Rugged Front

Batch Preset

Current Batch 
Quantity

Start, 
Batch Preset, 
Stop Keys

Batch Control & 
Alarm Relays

Total

super-Bright l eDs make standard and 

sunBright Display models even Brighter

The P

RO

V

U’

s standard and SunBright display models feature 

extraordinarily bright LED displays. They are perfect for indoor and 
outdoor applications where visibility may be impaired by smoke, 
fog, dust, or distance. The intensity on the SunBright model display 
is so high it can be read even in the brightest sunlight.

Free UsB Programming software & c able

The 

P

ro

V

u

®

 comes preloaded with free 

meterView

®

  Pro 

programming software that connects and installs directly to your PC 
with a standard USB cable, also provided free with each instrument. 
This eliminates the need to insert CDs, install drivers, or download 
software from the internet. The software will allow you to configure, 
monitor, and datalog a 

P

ro

V

u

®

 PD6210/6310 using your PC. Just 

simply connect the meter

 

to your PC with the USB cable and within 

minutes you will be programming it.

 

c learly l abeled Displays

The upper display alternates the display to show the controller state 
when in pause or stop mode. When displaying rate, grand total, 
batch count, or preset, the lower display alternates between the 
display value and the function or unit of measure.

a lternating Display

Batch t otal & Preset

Free USB Cable Included  

for Easy Software Installation

Summary of Contents for PRO VU Series

Page 1: ...ture C ount Up or Down with Each Batch C ommon PRO VU METER Fea t ures NEMA 4X IP65 Front Input Power O ptions Include 85 265 VAC or 12 24 VDC Dual L ine 6 Digit Display 0 60 0 46 Programmable Displays Function Keys O ptional SunBright Display Models for O utdoor A pplications 2 or 4 R elays Isolated 4 20 mA Output Options External 4 R elay Digital I O Expansion Modules RS 232 RS 485 Serial C ommu...

Page 2: ...may be displayed in the lower display with password protection and non resettable programmable features Dual Line 6 Character Display Large 0 6 Digits Rugged Front Batch Preset Current Batch Quantity Start Batch Preset Stop Keys Batch Control Alarm Relays Total Super Bright LEDs make Standard and SunBright Display Models Even Brighter The PROVU s standard and SunBright display models feature extra...

Page 3: ...CH key is configured by default to access the preset menu The preset may be changed quickly and easily between batches without the need to enter setup menus Non R esettable Grand T otal The user can set up the grand total to be non resettable by entering a specific password Once this is done the grand total can never be reset T otal C onversion Factor The user can enter a conversion factor that al...

Page 4: ...keys on the front panel without a password Level 2 protection allows the operator use of only the function keys and the ability to change set points without a password Level 3 protection restricts the function keys and all configuration menus without a password Grand total reset protection prevents the total from being reset manually R ugged A unique front panel design makes the PROVU nearly impen...

Page 5: ...batch total equals the preset amount the restricted flow valve closes The barrel is now full If some overrun occurs the next batch will adjust for this offset amount to maintain accuracy C hange Preset After placing a new empty barrel a new preset fill amount may be selected with the Batch key while the process is stopped Begin New Batch Press the START key and a new batch will begin With both val...

Page 6: ...ls rated 200 mA max 12 24 VDC powered models rated 100 mA max 50 mA max for 5 or 10 VDC supply Normal R ejection Mode Greater than 60 dB at 50 60 Hz PD6210 Isolation 4 kV input output to power line 500 V input to output or output to P supply O vervoltage C ategory Installation Overvoltage Category II Local level with smaller transient overvoltages than Installation Overvoltage Category III Environ...

Page 7: ... illuminated while displaying batch total and GT for grand total Up to 999 999 999 with total overflow feature oF is displayed to the left of grand total overflow and LED is illuminated Batch T otal Decimal Point Up to five decimal places or none d ddddd dd dddd ddd ddd dddd dd ddddd d or dddddd Total decimal point is independent of rate decimal point T otalizer Calculates total based on rate and ...

Page 8: ...loads or der ing informa t ion PRO VU PD6210 A nalog Input 85 265 VAC Model 12 24 VDC Model O ptions Installed PD6210 6R2 PD6210 7R2 2 Relays PD6210 6R4 PD6210 7R4 4 Relays PD6210 6R5 PD6210 7R5 2 Relays 4 20 mA Output PD6210 6R7 PD6210 7R7 4 Relays 4 20 mA Output To order SunBright display models replace the R with H i e PD6210 6H2 Note 24 V flowmeter power supply standard on all models PRO VU PD...

Reviews: