Malfunctions
52
Symptom
Possible cause
Remedy
Firing without a fastener
being driven in (empty
firing).
Spring of advancer
defective.
Contact Service (see
page 58).
The magazine is
soiled.
Clean the magazine.
Wrong fasteners
loaded into the
magazine.
Empty the magazine.
Fill the magazine with
PREBENA fasteners
(see page 26).
The tool is not
sufficiently lubricated.
Pour PREBENA special
nailer oil into the
compressed air port
used.
Fire several times.
Working pressure too
low.
Increase working
pressure (see page 33).
The plunger with the
driver does not return
to its starting position
after firing.
Contact Service (see
page 58).
The firing process is
not performed
completely.
Contact Service (see
page 58).
The driver is bent.
Contact Service (see
page 58).
A fastener is jammed.
Remove jammed
fastener (see page 48).
Otherwise contact
Service
(see page 58).