Servicing the Cartridge 

13 

Having the cartridge checked  

 

 

 

WARNING 

Risk of explosion due to unchecked cartridges. 

  Use properly checked cartridges only. 

 

 

 

 

The cartridge must be inspected at Prebena at intervals specified in 
national regulations every five years. This check must be 
documented in the intended field on the label of the cartridge. 

  Check the date of the last periodic check on the type label. 

If it dates back 5 years or more, proceed as follows: 

  Pack the cartridge in a sturdy shipping carton (see page 11). 

  Send the cartridge to PREBENA for inspection. 

Summary of Contents for KT-300

Page 1: ...79 Schotten Germany Tel 49 0 60 44 96 01 0 Fax 49 0 60 44 96 01 820 Email info prebena com www prebena de www kartuschen tausch de Original Operating Manual for the Cartridge PREBENA KT 3500 PREBENA KT 300 PREBENA KT 470 PREBENA KT 690 PREBENA KT 900 98678703 ...

Page 2: ...ling pressure containers and compressed air driven devices Persons without such knowledge must be instructed in cartridge usage by an experienced user Every person who uses fills cleans or disposes of the cartridge must take note of this operating manual This operating manual is part of the product Always keep it near the cartridge Pass this operating manual on if you sell the cartridge or hand it...

Page 3: ... label for KT 3500 7 Specifications on the type label for KT 300 KT 470 KT 690 and KT 900 8 Using the Cartridge 9 Checking the condition 9 Connecting the cartridge 9 Separating the cartridge from the device 10 Transporting and Storing the Cartridge 11 Servicing the Cartridge 11 Cleaning the cartridge 11 Filling the cartridge 12 Having the cartridge checked 13 Troubleshooting 14 Cartridge Disposal ...

Page 4: ...afety information in this operating manual is structured in the same way On the left you find a hazard symbol Right next to it you see a signal word indicating the severity of danger Below this you see a description about the source of danger and information about how you can avoid this hazard WARNING Information with the word WARNING warns of hazards that could possibly lead to severe or fatal in...

Page 5: ...nly permitted after consulting with the manufacturer Part of the intended use is observing the accident prevention regulations and the provisions and standards applicable on site Any other use is deemed as not intended and can lead to damage to property and even to damage to persons The following items are particularly deemed as not intended Operation on not permitted devices Operation with oxygen...

Page 6: ...ype label Separate the cartridge from the fastener driving tool and the controller before transport Keep the cartridge inaccessible for children and other unauthorised persons Do not use a cartridge if its periodic check dates back more than 5 years Avoid damaging the cartridge Never open the cartridge Always leave repair works to qualified experts Do not use the cartridge if it has been dropped o...

Page 7: ...ves on the cartridge the operating manual and the conformity Specification on the type label for KT 3500 A label is attached to the cartridge You can find the following important information about the cartridge on it No Explanation 1 End of operating life 2 Serial number of the cartridge 3 Manufacturing date month and year 4 Year of the first periodic check 5 Type designation of the cartridge 6 Co...

Page 8: ...ortant information about the cartridge on it No Explanation 1 End of operating life 2 Serial number of the cartridge 3 Manufacturing date month and year 4 Year of the first periodic check 5 Type designation of the cartridge 6 Country of origin 7 Company name 8 Date of the last periodic check that was carried out Do not remove or cover the type label ...

Page 9: ...r loose The cartridge must not show any external damage such as scrapes or dents The last periodic check of the cartridge must not date back more than five years The cartridge s operating life must not be exceeded Do not connect a damaged cartridge to a device Have the damaged cartridge repaired by PREBENA experts before connecting it Connecting the cartridge Take the cartridge from the transport ...

Page 10: ... on unsuitable devices can cause damage to the cartridge and the device Connect the cartridge to devices approved by the manufacturer only Slide the cartridge with the valve at the head into the brackets on the device Screw the cartridge hand tight into the thread at the device connection Separating the cartridge from the device Conduct the following steps after the operation or after service inte...

Page 11: ...cartridge to the desired location Store the cartridge at room temperature in a dry and dust proof location Servicing the Cartridge The cartridge must only be serviced by persons having the required knowledge skills and experience for that All works not described here must only be conducted by the manufacturer s customer service or at the manufacturer s premises Cleaning the cartridge Clean the hul...

Page 12: ...side of the valve Wipe the outside of the valve with a cloth slightly moistened with soap solution Then wipe the outside of the valve with a cloth slightly moistened with tap water Then scrub it with a soft and dry cloth It is not permitted to clean the cartridge with means other than the stated means If you are unable to clean the cartridge as described send it to the manufacturer Filling the car...

Page 13: ...ted at Prebena at intervals specified in national regulations every five years This check must be documented in the intended field on the label of the cartridge Check the date of the last periodic check on the type label If it dates back 5 years or more proceed as follows Pack the cartridge in a sturdy shipping carton see page 11 Send the cartridge to PREBENA for inspection ...

Page 14: ...tion for the cartridge The cartridge was loosened by shock Screw the cartridge hand tight into the connection see page 9 The gaskets on the connections for the cartridge are defective Connect new cartridge see page 9 Send cartridge to PREBENA via a specialist dealer see page 18 If the problem persists Send the fastener driving tool to PREBENA via a specialist dealer see page 18 No release possible...

Page 15: ... the manufacturer for disposal see page 18 Technical Data KT 3500 Length 410 mm Diameter 87 mm Packaging dimensions L W H KT 3500 S 270 115 435 mm Weight empty cartridge 1 3 kg Weight full cartridge 1 7 kg Weight KT 3500 S with transport case 7 kg Content 1 5 l compressed air Maximum container air pressure 300 bar Operating temperature 5 to 45 C Storage transport temperature Room temperature maxim...

Page 16: ...ort temperature Room temperature maximum of 60 C Maximum operating life 15 years from the date of manufacture KT 470 Length 505 mm Diameter 140 mm Packaging dimensions L W H KT 470 S 600 x 290 x 195 mm Weight empty cartridge 2 9 kg Weight full cartridge 4 54 kg Weight KT 3500 S with transport case 11 1 kg Content 4 7 l compressed air Maximum container air pressure 300 bar Operating temperature 5 t...

Page 17: ...port temperature Room temperature maximum of 60 C Maximum operating life 15 years from the date of manufacture KT 900 Length 575 mm Diameter 175 mm Packaging dimensions L W H KT 900 S 675 x 310 x 235 mm Weight empty cartridge 5 0 kg Weight full cartridge 8 1 kg Weight KT 3500 S with transport case 15 94 kg Content 9 0 l compressed air Maximum container air pressure 300 bar Operating temperature 5 ...

Page 18: ...urer Address PREBENA Wilfried Bornemann GmbH Co KG Fastening technology Seestraße 20 26 D 63679 Schotten Telephone 49 0 60 44 96 01 0 Telefax 49 0 60 44 96 01 820 Email info prebena de Homepage www prebena de www kartuschen tausch de ...

Page 19: ...ranty claim does not apply upon non compliance The warranty does not extend to wear parts such as O rings etc It is at PREBENA s discretion to undertake the warranty by exchanging the defective part or by substitute delivery There are no further claims In order to make claims under the warranty the properly filled out warranty certificate with dealer stamp and date of purchase or an invoice statin...

Page 20: ...PREBENA Wilfried Bornemann GmbH Co KG Seestraße 20 26 63679 Schotten Germany Tel 49 0 60 44 96 01 0 Fax 49 0 60 44 96 01 820 Email info prebena com www prebena de www kartuschen tausch de ...