38
ALERTS & ERRORS
Open Door Alert
When the Forza Express is in operation and for some reason it is necessary to open the door during
the execution of the recipe the message "Door Open" will be displayed on the screen.
This message will only leave the screen after the port has been closed.
Se durante a execução da receita esta mensagem aparece no visor mesmo que a porta esteja fechada
é possível que se tenha algum problema com o switch da porta.
NOTA: outra característica que indica algum problema com o switch é quando o forno, mesmo fora
de execução das receitas e com a porta fechada, emite um alerta sonoro pulsante.
Inverter Error
The display shows INV Error when there is no communication between the electronic board and the
frequency inverter.
This error can be caused by a fault in the inverter or its parameters, a problem with the cable or the
MODBUS connectors (ex. inverted connection or loose cable) and a problem with the inverter itself
or the electronic board (which may not recognize the Communication).
The inverter error occurs after 10 (ten) attempts of communication between the board and the
inverter.
While this error is present in the display, no oven operation is possible.
Summary of Contents for Forza Express
Page 5: ......
Page 6: ......
Page 7: ...1 SAFETY INSTRUCTIONS ...
Page 11: ...5 Specifications Installation ...
Page 12: ...6 SPECIFICATIONS INSTALLATION ...
Page 16: ...10 SPECIFICATIONS INSTALLATION ...
Page 17: ...11 DAILY CLEANING QUARTERLY MAINTENANCE ...
Page 24: ...18 DAILY CLEANING QUARTELY MAINTENANCE ...
Page 25: ...19 THEORY OF OPERATION ...
Page 27: ...21 USER SETTINGS ...
Page 37: ...31 MANUFACTURE SETTINGS ...
Page 42: ...36 MANUFACTURE SETTINGS ...
Page 43: ...37 ALERTS ERRORS ...
Page 46: ...40 ALERTS ERRORS ...
Page 47: ...41 IMPINGEMENT SYSTEM ...
Page 59: ...53 CONTROL SYSTEM ...
Page 64: ...58 CONTROL SYSTEM ...
Page 65: ...59 POWER COMPONENTS ...
Page 70: ...64 POWER COMPONENTS ...
Page 71: ...65 FILTERINGSYSTEM ...
Page 74: ...68 FILTERING SYSTEM ...
Page 75: ...69 FORZA EXPRESS SCHEMATICS ...
Page 76: ...70 FORZA EXPRESS SHEMATICS Control Board Schematic ...
Page 77: ...71 Heater Schematic ...
Page 78: ...72 FORZA EXPRESS SHEMATICS Blower Motor Cooling Fan Schematic ...
Page 79: ...73 Pictorial Diagram ...
Page 80: ...74 FORZA EXPRESS SHEMATICS ...
Page 81: ...EXPLODED VIEW PARTS LIST ...
Page 82: ...Assembly Level 1 ...
Page 83: ...Assembly Panel ...
Page 84: ...Inverter ...
Page 85: ...Assembly Door ...
Page 86: ...Assembly Level 2 ...
Page 87: ...Assembly Motor ...
Page 88: ...Assembly Level 3 ...
Page 89: ......