MICROWAVE SYSTEM
Door Switches
The Copa Express oven utilizes three independent
door switches to monitor the position of the door
during microwave operation. The switches are
referenced throughout this section as well as the
wiring diagram as: Primary, Secondary, and Monitor.
The Primary and the Secondary switches are located
on the right side of the oven. They can easily be
accessed by removing the right-side cover. The
purpose of these switches is to give two separate
signals back to the control board to ensure the door is
properly closed before the microwave can be
energized.
The Monitor switches is locked on the left side of the
oven and is used to act as a “fail safe” if
both the
Primary and the Secondary switches were to fail. This
switch is wired in series with a separate relay
(Interlock Relay) used to open a fuse and disable the
circuit. This dead short condition will occur if the
Monitor switch opens before either the Primary or
Secondary switch during a microwave event. The
three door switches must open in a specific order
when the oven door is opened: Primary, Secondary,
then lastly Monitor.
Note:
In the event of a “fail safe” condition and the fuse has opened
, all three door switches are
required to be replaced to insure continued functionality and performance.
Monitor Switch
Primary and Secondary Switches
Summary of Contents for Copa Express
Page 6: ...vi INDEX ...
Page 7: ...1 SAFETY INSTRUCTIONS ...
Page 11: ...5 SPECIFICATIONS INSTALLATION ...
Page 12: ...6 SPECIFICATIONS INSTALLATIONS Spec Sheet ...
Page 16: ...10 DAILY CLEANING QUARTERLY MAINTENANCE ...
Page 17: ...11 DAILY CLEANING QUARTERLY MAINTENANCE ...
Page 24: ...18 THEORY OF OPERATION ...
Page 25: ...19 THEORY OF OPERATION ...
Page 32: ...26 OVEN CONTROLS AND COOKING ...
Page 33: ...27 OVEN CONTROLS AND COOKING ...
Page 41: ...35 USER SETTINGS ...
Page 50: ...44 MANUFACTURE SETTINGS ...
Page 51: ...45 MANUFACTURE SETTINGS ...
Page 56: ...50 ALERTS ERRORS ...
Page 57: ...51 ALERTS ERRORS ...
Page 60: ...54 MICROWAVE SYSTEM ...
Page 61: ...55 MICROWAVE SYSTEM ...
Page 81: ...75 IMPINGEMENT SYSTEM ...
Page 92: ...86 CONTROL SYSTEM ...
Page 93: ...87 CONTROL SYSTEM ...
Page 97: ...91 POWER COMPONENTS ...
Page 102: ...96 FILTERING SYSTEM ...
Page 103: ...97 FILTERING SYSTEM ...
Page 106: ...100 COPA EXPRESS SCHEMATICS ...
Page 107: ...101 COPA EXPRESS SCHEMATICS ...
Page 108: ...102 COPA EXPRESS SCHEMATICS HMI Board Schematic ...
Page 109: ...103 Control Board Schematic ...
Page 110: ...104 COPA EXPRESS SCHEMATICS Heater Schematic ...
Page 111: ...105 Blower Motor cooling Fan Schematic ...
Page 112: ...106 COPA EXPRESS SCHEMATICS Microwave Circuit Schematic ...
Page 113: ...107 Pictorial Diagram The PPI team will post this information Similar to Rocket Express ...
Page 114: ...108 EXPLODED VIEW PARTS LIST ...
Page 115: ...109 EXPLODED VIEW PARTS LIST ...
Page 116: ...110 EXPLODED VIEW PARTS LIST Assembly Level 1 ...
Page 117: ...111 Assembly Door ...
Page 118: ...112 EXPLODED VIEW PARTS LIST Assembly Panel ...
Page 119: ...113 Inverter ...
Page 120: ...114 EXPLODED VIEW PARTS LIST Assembly Level 2 ...
Page 121: ...115 Door Hinge Assembly RHS ...
Page 122: ...116 EXPLODED VIEW PARTS LIST Door Hinge Assembly LHS ...
Page 123: ...117 Assembly Level 3 ...
Page 124: ...118 EXPLODED VIEW PARTS LIST Assembly Motor ...
Page 125: ...119 Electric Panel Assembly ...
Page 126: ...120 EXPLODED VIEW PARTS LIST Assembly Level 4 ...
Page 127: ...121 Gearmotor Assembly ...
Page 128: ...122 EXPLODED VIEW PARTS LIST High Voltage Assembly ...
Page 129: ......