GUARANTEE - In compliance with legislation, the manufacturer’s guarantee is valid from  the date stamped on the product and is restricted to the 
repair or free replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The 
guarantee does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect 
product, assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired.  
Printed  specifications  are  only  indicative.  The  manufacturer  does  not  accept  any  responsibility  for  range  reductions  or  malfunctions  caused  by 
environmental  interference. The manufacturer’s  responsibility for  damage caused  to  persons  resulting  from  accidents  of  any  nature caused  by  our 
defective products, are only those responsibilities that come under European law.

 

Caratteristiche tecniche  

Technical features

 

 

Frequenza 

Frequency 

868,3 Mhz  

Portata del sistema in campo libero 

Range of the system in free space 

30 m  

Alimentazione trasmettitore 

Transmitter power supply 

2 batterie / 

battery

 AA  

Alimentazione ricevitore 

Receiver power supply 

12/24 Vac

-

dc  

Durata batteria 

Battery duration 

2 anni (modalità funzionamento normale) 
5 anni (modalità risparmio energetico) 

2 years (normal functionning mode) 
5 years (power saved mode)  

Coste compatibili 

Compatible ribs  

Meccaniche e/o 8,2K 

Mechanical and/or 8,2K   

Numero di uscite 

Number of output 

Numero di costa associabili per 
ogni ricevitore 

Number of ribs for receiver  

4 per ogni uscita. 

4 for each output

13  TECHNICAL FEATURES 

By the dip switch Low Power present on the transmitter device it is possible to limit the frequency with which the transmitter device transmits its state 
of functioning (period of interrogation): but in this case it will be necessary to keep in consideration the condition of dangerous that can be created if 
the power supply (battery) is taken off to the transmitter during the interval of time before the successive transmission of its state and successively the 
sensible edge goes on alarm: in this case the receiver will signal the alarm only after the period of interrogation. 

 

With the dip 2 of the transmitter on OFF: energy saving deactivated, check the state of the transmitter each second (low power deactivated) 
With the dip 2 of the transmitter on ON: energy saving activated, check state of transmitter each 15 seconds (low power activated) 

11.  SAVING OF ENERGY (LOW POWER)

 

 

12.  DEVICES TEST 

By the dip switch 1 of the receiver it is possible to select if the device test must be carried out with a high logic signal (so the test will activate itself if 
between the terminals TEST1 and TESTC will be present a tension from 10V dc to 24 Vdc) or with a low logic signal (so the test will activate itself if 
between the terminals TEST1 and TESTC will be present a tension of 0Vdc). In this case, the test will be for the device memorized to the relay 1. The 
same is for TEST2  and TESTC for the device memorized to the relay 2. 
During this test, the receiver sends a signal to all the associated transmitter with the request of their state. If all the devices answer positively, the test 
is passed and the correspondent relay (which was previously open) re – closes itself. 

 
 

With the dip 1 of the receiver on OFF position: the test of the device is executed by applying a high logic signal 10-24 Vdc at the input. 
With the dip of the receiver on ON position: the test of the device is executed by applying a low logic signal 0 Vdc at the input.  
 
Note : in case you don’t want to use the test of the device, place the dip 1 on OFF position.  

WARNING: 

 

TCO7TX DIP1 OFF: mechanical safety edge (normally closed contact)

 

This application does not comply with the automatic doors security norm for use EN 12453 because the 
connection of the NON-resistive component connected to the transmitter is not checked.

 

ISTCO7KIT_EN_12-17.pdf 

Summary of Contents for TCO7RX

Page 1: ...ive edges TRANSMITTER TCO7TX TCO7RX TCO7TX Notified Body Directive 98 37 EC EC ident N 1844 PRASTEL FRANCE ZI Athélia II 225 Impasse du Serpolet 13704 LA CIOTAT Cedex FRANCE Tel 334 42 98 06 06 Fax 334 42 04 53 51 RECEIVER TCO7RX Bidirectional communication ...

Page 2: ...flat Transceiver system 1 DESCRIPTION 2 CONFIGURATION AND ELECTRICAL CONNECTIONS NOTE The signal given on output clean contact or 8 2K to the relay 1 and 2 depends on the position of the selection output signal jumper 2 1 Receiver TCO7RX Jumper of selection power supply tension Right 12Vac dc Left 24Vac dc Dip switch Programming reset key WARNING if the power supply of the TCO7RX is carried out in...

Page 3: ...ip 3 and dip 4 which will have to correspond to the one of the transmitters 5 The inputs are handled in the same way as the photocells test the control unit to carry out the photocells test switches off the power supply of the receiver and check that the relays of the correspondent receiver opens itself In this device the input TEST1 and TEST2 are for testing the security devices see chapter 12 MI...

Page 4: ...annel has been reached 1 Maximum time up for the memorization of the transmitter 10 second 5 3 Summary of the acoustic signalling during the learning phase Beside the two receiver relays a jumper for the selection of the type signal to give on output is present This signal can be 1 A clean contact open contact in case of alarm and close if the alarm is not present 2 A contact type 8 2K resistance ...

Page 5: ...r emits one uninterrupted bip N B If one transmitter is in alarm but it necessary to open or close the automation in any case it s necessary to press and keep pressed the programming test button of the indicted transmitter of the indicated and in the same time to move the automation WARNING If the batteries are completely flat it will be necessary to change them The battery life is of about 2 year...

Page 6: ...e it will be necessary to keep in consideration the condition of dangerous that can be created if the power supply battery is taken off to the transmitter during the interval of time before the successive transmission of its state and successively the sensible edge goes on alarm in this case the receiver will signal the alarm only after the period of interrogation With the dip 2 of the transmitter...

Reviews: